5 Parameter
BU 0180 en-4118
145
P542
[-01]
[-02]
Set analogue output
(Set analogue output)
S
0.0 ... 10.0 V
{ all 0.0 }
only with
SK CU4-IOE or
SK TU4-IOE
[-01] =
First IOE, AOUT of the
first
I/O extension (SK xU4IOE)
[-02] =
Second IOE, AOUT of the
second
I/O extension (SK xU4IOE)
The analogue output of the FI can be set with this function, independently of the actual operating
state. To do this, the relevant analogue output must be set to the function "External control"
(P418 = 7).
This function can either be used manually or in combination with a bus control. The value set here
will, once confirmed, be produced at the analogue output.
Changes which are made to the settings are not saved in the EEPROM. After "Power ON" of the
frequency inverter, the parameter is therefore in the default setting.
P543
[-01]
...
[-03]
Actual bus value 1 … 3
(Actual bus value 1 ...
3)
S
P
0 ... 55
{ [-01] = 1 }
{ [-02] = 4 }
{ [-03] = 9 }
The return status value can be selected for bus actuation in this parameter.
NOTE:
For further details, please refer to the relevant bus manual or the description for
(P418). (Values from 0% … 100% correspond to 0000
hex
… 4000
hex
)
For standardisation of the actual values: (please see chapter 8.9 "Standardisation of setpoint /
[-01] = Actual bus value 1
[-02] = Actual bus value 2
[-03] = Actual bus value 3
(Definition of frequencies (please see chapter 8.10 "Definition of setpoint and actual value
0 =
Off
18 =
Value of analogue input 2,
Analogue input 2 (P400[-02]),
1 =
Actual frequency
2 =
Actual speed
19 =
Setpoint frequency master value (P503)
3 =
Current
20 =
Target frequency aft. mast. val. ramp,
"Setpoint frequency after master value ramp"
4 =
Torque current (100% = P112)
5 =
Digital IO* status
21 =
Actual freq. without slip Master value
"Actual frequency without master value slip"
6 =
... 7 Reserved
8 =
Setpoint frequency
22 =
Reserved
9 =
Error number
23 =
Actual frequency with slip
(from software version V1.3)
"Actual frequency with slip"
10 =
... 11 Reserved
12 =
BusIO Out Bits 0-7
24 =
Master value
Actual freq.
w. slip
(SW 1.3 and above)
"Master value, actual freq. with slip"
13 =
... 16 Reserved
17 =
Value analogue input 1,
Analogue input 1 (P400[-01]),
53 =
Actual value 1 PLC
54 =
Actual value 2 PLC
55 =
Actual value 3 PLC
* assignment of the digital inputs for P543 = 5
Bit 0 = DigIn 1 (FI)
Bit 1 = DigIn 2 (FI)
Bit 2 = DigIn 3 (FI)
Bit 3 = DigIn 4 (FI)
Bit 4 = DigIn 5 (FI)
Bit 5 = PTC input [FI]
Bit 6 = reserved
Bit 7 = reserved
Bit 8 = DigIn 6 (DI1, 1. SK…IOE)
Bit 9 = DigIn 7 (DI2, 1. SK…IOE)
Bit 10 = DigIn 8 (DI3, 1. SK…IOE)
Bit 11 = DigIn 9 (DI4, 1. SK…IOE)
Bit 12 = DigOut 1 (FI)
Bit 13 = DigOut 2 (FI)
Bit 14 = reserved
Bit 15 = reserved
Содержание SK 180E Series
Страница 1: ...BU 0180 en NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters...
Страница 4: ...NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters 4 BU 0180 en 4118...
Страница 185: ...8 Additional information BU 0180 en 4118 185 8 3 4 EU Declaration of Conformity...
Страница 211: ...Key word index BU 0180 en 4118 211...
Страница 212: ...6071802 4118...