NORDAC BASE (SK 180E / SK 190E) – Users Manual for Frequency Inverters
126
BU 0180 en-4118
Value Function
Description
Signal
73
2
Clockw. d fast
"Disable clockwise rotation + Fast
Stop"
As for setting 31, however coupled to the function "Fast Stop".
Low
74
2
Anticlockw. d fast
"Disable anticlockwise rotation +
Fast Stop"
As for setting 32, however coupled to the function "Fast Stop".
Low
75
D. out. 2 man/ auto set
"Set
digital
output
2
manually/automatically"
As for function 67, however for digital output 2 (only SK 2x0E)
High
76
D. out. 2 man. set
"Set digital output 2 manually"
As for function 68, however for digital output 2 (only SK 2x0E)
High
77
...79 reserved
80
PLC - Stop
The program execution of the integrated PLC is stopped for as
long as the signal is present.
High
1
If no digital input is programmed for "Right enable" or "Left enable", the actuation of a fixed frequency or the jog frequency will
enable the frequency inverter. The rotation field direction depends on the sign of the setpoint.
2
Also effective for BUS control (e.g. RS232, RS485, CANopen, AS-Interface, …)
3
Function cannot be selected via BUS IO In Bits
4
The operating parameter set is selected using appropriately
parametrised digital inputs or by means of BUS actuation.
Switching can take place during operation (online). Coding
takes place in binary in accordance with the adjacent sample.
If enabled via the keyboard (SimpleBox, ControlBox,
PotentiometerBox or ParameterBox), the operating parameter
set will match the settings in P100.
Setting
Digital input
function [8]
Digital input
function [17]
0 =
Parameter set 1
LOW
LOW
1 =
Parameter set 2
HIGH
LOW
2 =
Parameter set 3
LOW
HIGH
3 =
Parameter set 4
HIGH
HIGH
P426
Quick stop time
(Quick stop time)
S
P
0 ... 320.00 sec
{ 0.10 }
Setting of the stop time for the fast stop function which can be triggered either via a digital input,
the bus control, the keyboard or automatically in case of a fault.
Emergency stop time is the time for the linear frequency decrease from the set maximum
frequency (P105) to 0Hz. If an actual setpoint <100% is being used, the emergency stop time is
reduced correspondingly.
P427
Emergency stop on error
(Emergency stop on error)
S
0 ... 3
{ 0 }
Activation of automatic emergency stop following error
0 = OFF:
Automatic emergency stop following error is deactivated
1 = Mains supply failure:
Automatic emergency stop following mains supply failure
2 = In case of faults:
Automatic emergency stop following fault
3 = Fault or mains failure:
Automatic emergency stop in case of fault or mains failure
An emergency stop can be triggered by the errors
E2.x, E7.0, E10.x, E12.8, E12.9
and
E19.0
.
Содержание SK 180E Series
Страница 1: ...BU 0180 en NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters...
Страница 4: ...NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters 4 BU 0180 en 4118...
Страница 185: ...8 Additional information BU 0180 en 4118 185 8 3 4 EU Declaration of Conformity...
Страница 211: ...Key word index BU 0180 en 4118 211...
Страница 212: ...6071802 4118...