Scrub System, Cylindrical
90
Service Manual – Condor
™
EcoFlex
™
, BR 1100/1300 EcoFlex
™
Scrub Deck Lift Actuator
Note:
All new replacement actuator motors are not shipped with the lift nut pre-adjusted for any
specific machine model application.
Note:
The scrub deck must be removed to access the top mount bracket on the scrub deck lift motor.
1
Remove the scrub deck by following the steps in the
Scrub Brush Deck
section
2 Locate and remove the upper
Cotter
Hair Pin
from underneath the middle
of the machine
3 Slide the actuator
Mount Pin
from the
housing and frame mounting bracket
holes allowing the motor to drop down
completing its removal
4 Refer to the
Drive Nut Adjustment
section for instructions on how to
install a new drive nut and set the
extended and retracted positions
5
Install the scrub deck actuator by
following the above steps in reverse
order
Service Note:
You can use the actuator power cord adapter (p/n 56407502) to help position
(extend or retract) the lift actuator housing for ease in installing the bottom
Mount
(clevis)
Pin
.
Cotter
Hair Pin
Mount
Pin
Mount
Pin
Cotter
Hair Pin