Solution System
119
Service Manual – Condor
™
EcoFlex
™
, BR 1100/1300 EcoFlex
™
Problem
Cause
Correction
Inadequate or no
detergent flow
The detergent system has
not been selected in the
main control programming.
Check that the detergent system has been selected
in the main control programming.
Blockage in or damage to
the detergent lines
Check detergent lines for blockage or damage and
repair/replace as necessary.
The detergent tank cap is
not sealed on the tank.
Tighten the tank cap. The detergent tank cap must
be seated securely and tight to pull (draw detergent)
from the tank.
The detergent pumps are
not operating.
•
Check the wire connections at the detergent
pumps for correct wiring polarity.
•
Make sure the electrical connections are tight and
corrosion-free.
•
With the system activated, touch the pumps to feel
them pulsate when operating. If a pump is getting
voltage but is not operating, replace the pump.
Removal and Installation
Warning! Before removing or reinstalling any machine components, make sure the key switch
is off, the key is removed from the machine and the parking brake is engaged.
Solution Control Pump
Note:
Access the solution control pump
from underneath the machine.
1
Drain the solution tank or turn the solution
shutoff valve to the off position to prevent
solution loss
2 Disconnect the battery from the machine
Note:
Place a suitable container
underneath the solution control
pump to catch any solution that
may leak from the pump or hoses.
3 Disconnect the pump
Electrical Connector
from
the machine harness
4 Remove the four
#10-24 Screws
, Nyloc
™
nuts and flat washers holding the
Solution Control Pump
to the
bottom of the machine
5 Loosen the
Clamps
holding the
Hoses
to the
Elbows
and disconnect (pry) the
Hoses
off of the
Elbows
6 Remove the
Solution Control Pump
from the machine
7 Reinstall the
Solution Control Pump
by following the above steps in reverse order
Solution
Control
Pump
Electrical
Connector
#10-24
Screw (4)
Clamp (2)
Hose (2)
Elbow (2)