Control System
30
Service Manual – Condor
™
EcoFlex
™
, BR 1100/1300 EcoFlex
™
Scrub Deck Down Time Adjustment
Note that the factory default deck down time is two seconds.
When scrub on switch is pressed, the control board will automatically lower the deck for two seconds. The
time that the deck is lowered is adjustable from one second to three seconds in 0.1-second increments.
To adjust the scrub deck down time:
1
Turn the key switch off.
2 Press and hold the scrub on and solution switches
3
While holding both switches, turn the key switch on.
4 Continue to hold both switches until both switch indicators turn on
5
Release both switches. The display will now show a clock icon in the upper left corner with a number
indicating the scrub deck down time period.
6 Press the scrub on switch to increment the time period Each press of the switch increments the scrub
deck down time 0.1 seconds. For example, the time will increment from 2.0 seconds to 2.1 seconds, and
so on. The deck down times range from 1.0 to 3.0 seconds.
7
Press the scrub off switch to save the new setting and display the key switch icon.
8
Turn the key switch off. The new setting will be saved until changed again.
Normal (Light) Scrub Setting Adjustment
Note that the factory default settings for the normal scrub setting are: Scrub pressure – one bar, Solution
flow rate – one bar.
The scrub pressure and solution flow rate for the normal scrub setting can be programmed to better suit a
particular application. This allows you to select a higher solution flow rate with normal scrub pressure, or
a normal solution rate with heavier scrub pressure, etc , as the normal scrub setting To change the normal
scrub settings:
1
Turn the key switch off.
2 Press and hold the scrub on and scrub speed switches
3
While holding both switches, turn the key switch on.
4 Continue to hold both switches until the scrub speed indicator turns on and the normal scrub on
indicator blinks.
5 Release both switches The display will now show a scrub icon (either disc or cylindrical) with the
current scrub pressure setting
6 Press the scrub on switch to increment the scrub pressure setting as shown by the number of bars in the
display
7
Press the scrub off switch to save the new scrub pressure setting and move to the solution flow rate
setting The display will now show the solution icon with gauge The normal scrub indicator will stop
blinking and the solution system indicator will blink.
8
Press the solution switch to increment the solution flow rate as shown by the number of bars in the
display