Electrical System
54
Service Manual – Condor
™
EcoFlex
™
, BR 1100/1300 EcoFlex
™
Low-voltage Cut-out Feature
All models discussed in this manual are equipped with a low-voltage cutout feature to prevent over-
discharging of the batteries. When a machine’s battery pack voltage falls below a specifically defined
threshold (voltage settings), the scrub system automatically shuts down The drive motor will still operate in
the low-voltage cut-out mode to allow the machine to be driven to a charging location
The low-voltage cut-out level is adjustable The standard lead-acid battery (wet cell) setting is 1 72 volts per
cell The alternate maintenance-free battery (gel cell) setting is 1 81 volts per cell The standard lead-acid
battery setting is factory-selected and should be used unless the battery manufacturer specifies the higher
cut-out voltage
Service Note:
A minimum recharge voltage of 2.13 volts per cell must be reached to allow the
scrub and solution systems to function again (reset). A 36-volt battery pack must
increase to a 38.6-volt minimum.
Battery Condition Indicator
The battery indicator displays the state of battery charge Five vertical bars indicates a fully-charged
battery after a complete charging cycle. The battery indicator will retain the state-of-charge even if the key
switch has been turned off The state-of-charge indicator is reset to full charge when the batteries have been
recharged It is also possible to choose between two different low-voltage thresholds depending on whether
maintenance-free or standard (lead-acid) batteries are being used (Have a qualified service engineer perform
this selection* )
Note:
The following percentages are based on usable battery capacity, not total battery capacity.
Therefore, 100% discharge = 80% of total battery capacity for standard wet-cell batteries, or
70% of total battery capacity for maintenance-free batteries.
Battery Indicator
Standard
Alternate
5 vertical indicator bars
36.1+
36.1+
4 vertical indicator bars
35.5-36.1
35.5-36.1
3 vertical indicator bars
34.4-35.5
34.4-35.5
2 vertical indicator bars
33.9-34.4
33.9-34.4
1 vertical indicator bars
32.2-33.9
33.3-33.9
0 vertical indicator bars
30.9-32.2
32.8-33.3
Low-voltage Cut-out
<30.9
<32.8