Specifications
Solution Flow Rates
Standard Flow Rates
Override Flow Rates
1 bar
2 bars
3 bars
4 bars
5 bars
40” Disc
.84 GPM
1.00 GPM
1.50 GPM
2.00 GPM
2.50 GPM
40” Cylindrical
.70 GPM
.84 GPM
1.00 GPM
1.50 GPM
2.50 GPM
45”/48” Disc
1.00 GPM
1.50 GPM
2.00 GPM
2.25 GPM
2.50 GPM
45”/48”
Cylindrical
.84 GPM
1.00 GPM
1.50 GPM
2.00 GPM
2.50 GPM
Component Specifications
Component
Specifications
Solution Control Pump
Voltage - 36 VDC
Current Draw - 3.9 amps max.
Flow Rate - 3.3 GPM @ 2.75 amps with 20 psi inlet
pressure
Solution Solenoid Valve
Coil Voltage - 36 VDC
Coil Resistance - 74 ohms
Accessory Pump
Voltage - 36 VDC
Current Draw - 3.0 amps max.
Pressure Control Setting - 100 ±5 psi
Maximum Flow Rate - 1.6 gal/min
Detergent Pump
Voltage - 24 VDC
Flow Rate - 87 ±3 ml/min