Control System
49
Service Manual – Condor
™
EcoFlex
™
Designation Pin ID
Wire ID/
Color
Description
Signal
Characteristics
Nominal
Value (when
activated)
Reference
To:
Acceptable
Range
Comments
Output
J1-13
GRA
UI Panel -
Ground
Voltage
0V
B- (ground)
0 - 1V
Provides ground to User Interface panel
Input
J1-14
BLK
Battery -
Voltage
0V
B- (ground)
0 - 1V
Input
J1-15
VIO
B
Voltage
36V
B- (Ground)
31V - 38V
Downstream of circuit breaker F2, switched
through contactor K5
Output
J1-16
WHT/VIO
Center Brush
Contactor
Voltage
0V
B- (ground)
0 - 1V
Output
J1-17
GRA/RED
Right Brush
Contactor
Voltage
0V
B- (ground)
0 - 1V
Output
J1-18
YEL/GRN
Solenoid Valve
Pulsed Voltage
0 or 36V
B- (ground)
see comment
Line should alternate between 0V and 36V
when solenoid is activated
Output
J1-19
YEL/BLU
Left Brush
Contactor
Voltage
0V
B- (ground)
0 - 1V
Output
J1-20
BLU/RED
Horn (-)
Voltage
0V
B- (ground)
0 - 1V
Output
J1-21
BLU/ORN
Solution Pump
(-)
PWM
0 or -36V
B+
see comment
below **
Pulsed PWM signal. Switched ground return
for pump.
Output
J1-22
WHT/BRN
UI Panel -
Power Supply
Voltage
+8V
B- (ground)
7 - 9V
Provides power to User Interface panel
Input
J1-23
VIO
B
Voltage
36V
B- (Ground)
31V - 38V
Downstream of circuit breaker F2, switched
through contactor K5
Output
J2-1
WHT/GRN
Squeegee
Ac
Voltage
36V
J2-9
see comment
+36V while lowering, -36V while raising
Input
J2-2
BRN
Scrub Brush
Motor Shunt
Voltage
.03 - .3V
B- (ground)
.03 - .3V
Input
J2-3
ORN/BLU
Vacuum Motor
Shunt
Voltage
.10V (Single
Vac)
.20V (Dual
Vac)
B- (ground)
.07 - .12V
(Single Vac.
Motor)
.15 - .24V
(Dual Vac.
Motor)
Recovery Tank Full voltage = .083V (Single
Vacuum Motor)
Recovery Tank Full voltage = .166V (Dual
Vacuum Motor)
Output
J2-4
ORN/BLK
Battery -
Voltage
0V
B- (ground)
0 - 1V
Return path for Scrub Deck Resistor
Output
J2-5
YEL/GRA
Brush
Actuator -
Voltage
36V
J2-6
see comment
-36V while lowering,
+36V while raising
Output
J2-6
RED/BLK
Brush Actuator
+
Voltage
36V
J2-5
see comment
+36V while lowering,
-36V while raising