Control System
35
Service Manual – Condor
™
EcoFlex
™
, BR 1100/1300 EcoFlex
™
7
Press the scrub off switch to save the setting and display the key switch icon.
8
Turn the key switch off. The new setting will be saved until changed again.
Solution Flow in Reverse Enable/Disable
Note that the factory default setting for the solution flow in reverse option is
ENABLE
The solution flow is programmed to dispense solution when the machine backing up. To disable solution flow
when the machine moves in reverse:
1
Turn the key switch off.
2 Press and hold the EcoFlex
™
button and the solution switch
3
While holding both the button and switch, turn the key switch on.
4 Continue to hold the button and switch until the solution system and vacuum/wand indicators turn on
5 Release the button and switch The vacuum/wand indicator will turn off, the solution system indictor
will blink and the scrub off indicator will turn on. The display will now show the message
SOLUTION IN
REVERSE
/
ENABLE
or
DISABLE
6 Press the solution switch to toggle between
SOLUTION IN REVERSE ENABLE
or
DISABLE
If you select
ENABLE
, the solution flow will stay on when the machine is moving in reverse. If you select
DISABLE
,
solution flow will stop when the machine is moving in reverse.
7
Press the scrub off switch to save the setting and display the key switch icon.
8
Turn the key switch off. The new setting will be saved until changed again.
Indicator LED Intensity Selection Option
Note that the factory default setting for the indicator LED intensity is normal
To change the intensity of the LEDs in the control panel indicators
1
Turn the key switch off.
2 Press and hold the vacuum/wand and scrub speed switches
3
While holding both switches, turn the key switch on.
4 Continue to hold both switches until the vacuum/wand and scrub speed indicators turn on The display
will now show a light bulb icon in the upper left corner indicating the LED light intensity selection
5 Release both switches The scrub speed and scrub off indicators will light and the vacuum/wand
indicator will blink.
6 Press the vacuum/wand switch to select between the normal intensity or extra bright intensity levels
7
Press the scrub off switch to save the setting and display the key switch icon.
8
Turn the key switch off. The new setting will be saved until changed again.