Scrub System, Cylindrical
88
Service Manual – Condor
™
EcoFlex
™
, BR 1100/1300 EcoFlex
™
Scrub Brush Deck
Warning! Engage the parking brake and chock both rear wheels so the machine can’t roll.
1 Loosen the four side
skirt
Retainer Knobs
(two per side) and
remove the
Side Skirt
Assemblies
from the
deck.
2 Slide out the
Hopper
3 With the scrub
brushes installed in
the deck, press the
Scrub On button to
lower the deck to the
floor.
Service Note:
Once the brush deck is in the lowered position, don’t turn the key switch off until
you disconnect the battery pack (push in the Emergency Disconnect). This will
prevent the scrub deck from automatically rising when the key is turned off.
4
Turn the key switch off.
5 Remove the
Solution Feed Hose
at the solution solenoid valve located underneath the left side of the
machine ahead of the rear wheel
6 Remove bottom lift actuator
Cotter Hair Pin
, then push the
Retainer Pin
from its housing and mount
bracket holes.
7 Disconnect the actuator wire harness connector Note that this will prevent the actuator from being
switched on and rising when it is disconnected from its deck mount.
Service Note:
Connect the Advance power cord adapter (p/n 56407502) to the lift motor harness,
then position (relieve the pressure on) the
Retainer Pin
for ease of removal.
8 Note the correct brush motor wire connections at each individual motor, then remove all the wiring from
the motor terminals
9 Locate the
ID
(identification)
Resistor Plug
on the scrub brush deck and separate its connector.
Retainer
Knob (4)
Side Skirt
Assembly
Hopper
Solution
Feed Hose
Cotter
Hair Pin
ID Resistor
Plug
Hex
Nut (4)
Pivot
Support
Arm (4)
Scrub Deck
Actuator
Spring Housing
Assembly
Retainer
Pin