Control System
29
Service Manual – Condor
™
EcoFlex
™
, BR 1100/1300 EcoFlex
™
3
While holding both switches, turn the key switch on.
4 Continue to hold both switches until both switch indicators turn on The display will show a wrench icon
indicating fault detection mode
5
Release both switches. The solution system indictor light will blink and the scrub off indicator will stay
on
6 Press the solution switch to toggle the fault detection between enabled/on (wrench icon with no cross) or
disabled/off (wrench icon with cross)
7
Press the scrub off switch to save the new setting and display the key switch icon.
8
Turn the key switch off. The new setting will be saved until changed again.
To Display the Control Board Revision Level
1
Turn the key switch off.
2 Press and hold both the scrub off switch and traction control switch
3
While holding both switches, turn the key switch on.
4 Continue to hold both switches until the scrub off and traction control indicators light
5 Release both switches The scrub off and traction control indicators will switch off The display will show
the
MAIN REVISION
of the A2 control board assembly, the
DISPLAY REVISION
of the A3 switch/display
panel assembly and the key switch icon.
6
Turn the key switch off.
Monitor Mode
The control system allows the five machine settings listed below to be quickly checked in the monitor mode
to view the machine’s specific setup. To enter the monitor mode and view the current machine settings:
1
Turn the key switch off.
2 Press and hold the detergent switch
3
While holding the detergent switch, turn the key switch on.
4 Continue to hold the detergent switch until the detergent system indicator switches on
5 Release the detergent switch The display
will show the following current machine
programmed settings:
• Scrub deck type and size,
•
Detergent mode on/off,
•
Fault detection on/off,
•
Vacuum motor selection –
VACUUM–SINGLE
(one motor) or
VACUUM–DUAL
(two motors)
6
To exit the monitor mode, turn the key switch off.