GB
Note: “
” represents the factory setting
Note (1): Automatically regulates the force required, maintaining a minimum guaranteed force level.
Note (2): Automatically regulates the force required.
All parameters can be adjusted as required without any contraindications, only the “Obstacle detection sensitivity” and “Motor force control”
may require special attention:
• Use of high force values are not recommended to compensate for the fact that the leaf has anomalous points of friction; excessive force
may impair the safety system and damage the leaf.
• If the “Obstacle detection sensitivity” is used in support of the system for impact force reduction, after each adjustment the force mea-
surement procedure must be performed, as envisaged by standard EN 12445.
• Wear and atmospheric conditions that influence movement of the gate; force settings should be checked periodically.
Partial Open
Maintenance
warning
Fault list
L1
L2
L3
L4
L5
L6
L7
L8
L1
L2
L3
L4
L5
L6
L7
L8
L1
L2
L3
L4
L5
L6
L7
L8
0,5 mt
1 mt
1,5 mt
2 mt
2,5 mt
3 mt
3,4 mt
4 mt
Automatic (based on seriousness of
manoeuvres)
2.000
4.000
7.000
10.000
15.000
20.000
30.000
Manoeuvre 1 result (most recent)
Manoeuvre 2 result
Manoeuvre 3 result
Manoeuvre 4 result
Manoeuvre 5 result
Manoeuvre 6 result
Manoeuvre 7 result
Manoeuvre 8 result
Input LED
Parameter
Led (level)
Value
Description
The measurement of the partial opening. Par-
tial opening can be controlled with the 2nd
radio command or with “CLOSE”, if the “Clo-
se” function is present, this becomes “Partial
open”.
Adjusts the number of manoeuvres after
which it signals the maintenance request of
the automation (see paragraph “7.4.4 Main-
tenance warning”).
The type of defect that has occurred in the
last 8 manoeuvres can be established (see
paragraph “7.6.1 Malfunctions archive”).
L6
L7
L8
7.2.4) Level two programming (adjustable parameters)
The adjustable parameters are factory set as shown in the table 9, with: “
” However, they can be changed at any time as shown in Table
10. Follow the procedure carefully, as there is a maximum time of 10 seconds between pressing one key and another. If a longer period of
time lapses, the procedure will finish automatically and memorize the modifications made up to that stage.
1.
Press and hold key
[Set]
(approx. 3 s)
3s
2.
Release the
[Set]
key when L1 LED starts flashing
L1
3.
Press key
[
▲
]
or
[
▼
]
to move the flashing LED onto the input LED representing the parameter to
be changed
or
4.
Press the key
[Set]
and hold it down during step 5 and 6
5.
Wait approx. 3 seconds, after which the LED representing the current level of the parameter to be
modified will light up.
6.
Press key
[
▲
]
or
[
▼
]
to move the LED representing the parameter value.
or
7.
Release the key
[Set]
8.
Wait 10 seconds before leaving the programme to allow the maximum time to lapse.
10s
Note: Points 3 to 7 can be repeated during the same programming phase in order to set other parameters
Tabella 10: changing the adjustable parameters
Example
SET
SET
SET
SET