20
Check of number of manoeuvres performed
The number of manoeuvres performed as a percentage of the set limit can be verified by means of the “Maintenance warning” function.
Follow the indications in table 17 for this check.
1.
Press and hold
[Set]
(approx. 3 s)
3s
2.
Release
[Set]
when led L1 starts flashing
L1
3.
Press key
[
▲
]
or
[
▼
]
to move the flashing LED onto the input LED L7 representing the “Maintenance
warning” parameter
or
L7
4.
Press and hold
[Set]
during steps 5, 6 and 7
5.
Wait approx. 3 seconds, after which the LED representing the current level of the parameter
“Maintenance warning” will light up.
3s
6.
Press and immediately release the
[
▲
]
and
[
▼
]
keys.
and
7.
The LED that corresponds to the selected level flashes. The number of flashes indicates the percentage
of manoeuvres performed (in multiples of 10%) in relation to the set limit.
For example: with the maintenance warning set on L6 being 10000, 10% is equal to 1000 manoeuvres;
if the LED flashes 4 times, this means that 40% of the manoeuvres have been reached (between 4000
and 4999 manoeuvres).
The LED will not flash if 10% of the manoeuvres has not yet been reached.
8.
Release the key
[Set]
Table 17: check of the number of manoeuvres performed
Example
SET
SET
SET
SET
....
n=?
Manoeuvre counter reset
After the maintenance of the system has been performed the manoeuvre counter must be reset.
Proceed as described in table 18.
1.
Press and hold
[Set]
(approx. 3 s)
3s
2.
Release
[Set]
when led L1 starts flashing
L1
3.
Press key
[
▲
]
or
[
▼
]
to move the flashing LED onto the input LED L7 representing the
“Maintenance warning” parameter
or
L7
4.
Press and hold
[Set]
during steps 5 and 6
5.
Wait approx. 3 seconds, after which the LED representing the current level of the parameter
“Maintenance warning” will light up.
3s
6.
Press and hold keys
[
▲
]
and
[
▼
]
, for at least 5 seconds and then release.
The LED that corresponds to the selected level flashes rapidly indicating that the manoeuvre
counter has been reset.
and
7.
Release the key
[Set]
.
Table 18: manoeuvre counter reset
Example
SET
SET
SET
SET
7.5) Connection of Other Devices
If the user needs to feed external devices such as a proximity read-
er for transponder cards or the illumination light of the key-operated
selector switch, it is possible to tap power as shown in Figure 27.
The power supply voltage is 24Vdc -30% - +50% with a maximum
available current of 100mA.
-
+
24Vcc
27