4.1
Maximum Output Current and Operation Range
HSA42011
4-2
4.1 Maximum Output Current and Operation Range
This product has a protection circuit that detects an output current and internal loss to limit the output
current. A maximum output current is determined by this protection circuit. This limitation value varies,
depending on the output time and output voltage. The relationships are shown in "
Figure 4-1
Operation Range
".
Each graph shows an AC (40 Hz) peak value range and a DC range.
In general, if the load is resistive for an AC signal, quadrants I and III cover an operation range. If the load
is capacitive or inductive, all four quadrants cover an operation range.
If the load involves an electromotive force with a DC signal, and an operation is performed to supply
current from the load, quadrants II and IV cover an operation range.
For square wave input, when waveform rise/fall is fast, even if a lower frequency (period) is used, the
output current protection range may be reached by a charge current for output cable capacitance or stray
capacitance inside this product, resulting in overload even if no load. In this case, decrease output voltage
or slow the waveform rise/fall by using a signal generator (e.g., WF1947) that is capable of controlling
waveform rise/fall.
Figure 4-1. Operation Range
-100
-80
-60
-40
-20
0
20
40
60
80
100
-2.0
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
2.0
AC
DC
Output Voltage
[V]
Output Current
[A]
Содержание HSA42011
Страница 1: ...NF Corporation HIGH SPEED BIPOLAR AMPLIFIER HSA42011 INSTRUCTION MANUAL...
Страница 2: ......
Страница 3: ...DA00082229 001 HIGH SPEED BIPOLAR AMPLIFIER HSA42011 INSTRUCTION MANUAL...
Страница 4: ......
Страница 18: ......
Страница 30: ......
Страница 46: ......
Страница 80: ......
Страница 82: ......
Страница 84: ......
Страница 85: ......
Страница 86: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...