3.3
I/O Terminals
HSA42011
3-7
3.3.3 Monitor output connector
This product has a monitor output connector for observing an output voltage. An output waveform can be
observed by connecting an oscilloscope directly to the connector.
The monitor output connector outputs a voltage, regardless of the output on/off setting. A voltage as small
as 1/100 of the main output level is output.
Output terminal
BNC connector (rear)
Monitor ratio
1/100 of output voltage (in phase as output voltage)
Output impedance
50
3.3.4 External control I/O connector
This product has an external control I/O connector with D-sub 9 pins.
To turn on output with the external control I/O function, turn on the power after depressing DIP switch 4
to be set at Power-on. (A DIP switch setting change made after operation is started is not reflected.)
Output on/off control can be exercised externally by using a no-voltage contact. (About the example used
external switch Refer to “
Figure 3-5. Example for I/O control by using external switch
”.)
If output is turned on with the external control I/O function, the output on/off switch (OUTPUT) on the
front panel can only be set to OFF.
To turn on output again after output is turned off using the output on/off switch (OUTPUT), the control
signal must first be turned off prior to turning on.
The overload state and output on/off state can be monitored externally. The overload state is indicated
when a short circuit is made between pins 3 and 8. The output on state is indicated when a short circuit is
made between pins 9 and 5.
After the external signal input level was changed, approx. 10 ms or more might be required for the
controller to execute a function as a maximum response time. “Output ON/OFF” additionally requires the
similar time for a response of a relay device.
Table 3-1. List of External Control I/O Connector Pins
(See "
Figure 3-4 External Control I/O
".)
Pin No.
Name
Description
1
+5 V
Power supply for external output on/off (50 mA or less)
6
External output on/off (A)
Connected to the primary side of the photocoupler via
150
2
External output on/off (K)
7 +5
V
common
Connected to the +5 V common potential (chassis
potential) via 100
4 Not
used
3 Overload
(C)
The overload state is set when a
short circuit is made
between pins 3 and 8.
(15 V or less and 10 mA or less between the pins)
8 Overload
(E)
9
Output on/off (C)
The output on state is set when a
short circuit is made
between pins 9 and 5.
(15 V or less and 10 mA or less between the pins)
5
Output on/off (E)
Содержание HSA42011
Страница 1: ...NF Corporation HIGH SPEED BIPOLAR AMPLIFIER HSA42011 INSTRUCTION MANUAL...
Страница 2: ......
Страница 3: ...DA00082229 001 HIGH SPEED BIPOLAR AMPLIFIER HSA42011 INSTRUCTION MANUAL...
Страница 4: ......
Страница 18: ......
Страница 30: ......
Страница 46: ......
Страница 80: ......
Страница 82: ......
Страница 84: ......
Страница 85: ......
Страница 86: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...