4.12 Auto-sequence
FRA5087
4-33
4.12.3 Deleting key sequence
Select [DELETE] in the menu [AutoSeq.] and press the
OPEN
key, first. Then, press the
function key [YES] to delete the stored/recorded key sequence.
4.12.4 Other remarks on auto-sequence
a)
File operations during recording/storage of and execution of auto-sequence
The recorded/stored key sequence can be saved or loaded in the USB flash drive together with
the measurement condition file.
When the measurement condition file is saved midway during the recording/storage of
key sequence, the previously recorded key sequence will be stored in the disk.
When the measurement condition file is loaded midway during the recording/storage of
key sequence, the key sequence will once be rewritten by the loaded content, but it will
again be rewritten by the new key sequence by the completion of recording/storage.
When the measurement condition file is saved midway during the execution of key
sequence, the currently recorded key sequence will be saved in the disk.
When the measurement condition is loaded midway during the execution of key
sequence, the recorded key sequence will be rewritten by the loaded sequence content.
However, the sequence currently being executed will be maintained with the content at
the start of execution until the sequence execution is completed. When again a
sequence is executed afterwards, the newly loaded sequence will be executed.
b)
Auto-sequence mode change during recording/storage of and execution of
auto-sequence
If the auto-sequence is deleted midway during recording/storage of sequence, the sequence
content is deleted, but it will be rewritten by the new key sequence after the recording/storage
operation is completed.
If the auto-sequence is deleted midway during execution of sequence, the recorded sequence
content is deleted, but the sequence currently being executed will be maintained with the
content at the start of execution until the sequence execution is completed. However, if you
try to execute a sequence again after the sequence has been completed, no sequence will be
executed unless a sequence is again recorded, since the recorded content has already been
deleted.
Содержание FRA5087
Страница 1: ...NF Corporation FREQUENCY RESPONSE ANALYZER FRA5087 INSTRUCTION MANUAL...
Страница 2: ......
Страница 3: ...DA00014460 004 FREQUENCY RESPONSE ANALYZER FRA5087 INSTRUCTION MANUAL...
Страница 4: ......
Страница 35: ...2 2 Mounting and installation FRA5087 2 7 Fig 2 3 Removal of foot stands...
Страница 40: ...2 6 Calibration FRA5087 2 12 Blank...
Страница 120: ...4 19 Condition display FRA5087 4 46 Blank...
Страница 134: ...5 6 Max min search function FRA5087 5 14 Blank...
Страница 158: ...7 2 Quick diagnosis FRA5087 7 8 Blank...
Страница 170: ...8 5 Performance test FRA5087 8 12 Blank...
Страница 190: ......
Страница 192: ......
Страница 193: ......
Страница 194: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima higashi Kohoku ku Yokohama 223 8508 JAPAN...