5. Position the riser assembly in the chassis, making sure that it aligns with the connector and guide pin on
the system board; then, insert the riser assembly.
6. Carefully press the riser assembly in place along its center line, next to the blue-marked holes, until it is
fully seated.
7. Remove the protective caps from the Fibre Channel HBA ports where you will be reinstalling cables.
After you finish
If you have no other maintenance procedures to perform in the controller, reinstall the controller cover.
Reinstall SG6000-CN controller cover
Change link configuration of SG6000-CN controller
You can change the Ethernet link configuration of the SG6000-CN controller. You can
change the port bond mode, the network bond mode, and the link speed.
What you’ll need
The appliance has been
.
About this task
Options for changing the Ethernet link configuration of the SG6000-CN controller include:
• Changing
Port bond mode
from Fixed to Aggregate, or from Aggregate to Fixed
• Changing
Network bond mode
from Active-Backup to LACP, or from LACP to Active-Backup
• Enabling or disabling VLAN tagging, or changing the value of a VLAN tag
• Changing the link speed.
Steps
1. From the StorageGRID Appliance Installer, select
Configure Networking
>
Link Configuration
.
157