Diagnostic Code
Description
S4
The power supply is incapable of powering the controller, which results
in a suspended controller state.
S5
The SBB pairing fails, which results in a suspended controller state.
Things to know - Seven-segment display use cases
The following table shows both startup errors and operation errors that can be used to point to a
component failure.
Seven-segment display uses cases with repeating sequences
Use cases
Repeating sequence
Use case: Controller power-on
•
Normal power-on controller insertion
•
Controller inserted while held in reset
SE+ 88+ blank-
Use cases
Repeating sequence
Use case: Operational states
•
Normal operation
xy-
(static controller tray ID)
•
Start-of-day (SOD) processing
OS+ Sd+ blank-
•
The controller is placed in reset while showing the
tray ID.
OS+ OL+ blank-
•
The controller is operating on batteries (cache
backup).
OS+ bb+ blank-
•
The CPU temperature has exceeded the warning
level.
OS+ OH+ blank-
Use cases
Repeating sequence
Use case: Component failure when the controller is
operational.
•
Failed host interface card
OS+ CF+ HX+ blank-
•
Failed flash drive
OS+ CF+ Fx+ blank-
Use Cases
Repeating sequence
Use case: Power-on diagnostic failure
Step 10 - Turning on the power and checking for problems in a controller-drive tray configuration | 131
Содержание E2760
Страница 2: ......