Installation and programming manual
Installation
23
Chapter 3
INSTALLATION
3-1
Installing the control panel
3-1-1
Wall-mounting
The control panel should be located in a secure location that can be accessed
by authorized building occupants only.
1. Using the backbox (
Table 4: Control panels - description of parts, G
),
mark the anchor screw locations on the wall. Be sure not to drill in the
vicinity of electrical wiring or plumbing/gas pipes, etc.
2. Insert the screw anchors (recommended size 6mm).
3. Pull the wires through the wire entry.
4. Using the screws, attach the backbox to the wall.
5. Fit the dislodgement-tamper microswitch (provided with SmartLiving
10100L, optional for SmartLiving 505, 515 and 1050, refer to
Appen-
dix H, Order codes, TamperNO
).
5.1. Insert the dislodgement-tamper bracket [A] into its location on
the backbox of the control panel (
Table 4: Control panels -
description of parts, H
).
5.2. Using screw location [B], screw the bracket to the wall.
5.3. Connect the wire coming from the dislodgement-tamper
microswitch [C] to the connector [D] on the board (
Table 4:
Control panels - description of parts, T
).
Note
The cable gland must be flame class rating V-1 or higher.
3-1-2
Connecting the Mains power
supply
The control panel must be powered through a separate line coming from the Mains box.
The line must be protected by a safety-standards compliant circuit breaker (trip switch).
The circuit breaker (trip switch) must be located externally to the apparatus and should
be easily accessible. The distance between contacts must be at least 3mm. The
manufacturer strongly advises the use of a magnetothermic switch with C intervention
curve and nominal (maximum) current - 16A.
The protective earthing system must be compliant with all safety standards and laws in
force.
DANGER!
Ensure that the Mains is switched Off during the mains connection phase. Danger of
electric shock.
The 505 and 515 models
The 505 and 515 models are powered by an external AC power pack.
The 1050 and 10100L models
Pull the cable through the cable entry [E], then connect the mains power to the power-
supply terminal board [D], located on the backplate above the motherboard. When
connecting the earth wire, follow the indications on the power-supply label [F]. The
power-supply provides power to the system and supplies the charge voltage.
A
B
C
D