Installation and programming manual
Options and programming methods
67
Via Keypad
1. Accessing the “Events” section
Type-in Code
(Installer PIN)
, PROGRAMMING Events
.
2. Use keys
and
to select the event type (if you are dealing with a group
of events, repeat the required operation) and , then press
.
3. Select:
•
Activation
- to programme the actions to be carried out when the event occurs.
•
Restoral
- to programme the actions to be carried out when the event ends.
4. Successively, the parameters to programme are:
TelephoneNumbers
Programme the call recipient numbers
Message type
Message A
Message B
Select the number of the message (see
Table 46: Event-related messages
and
Appendix D, Voice messages
):
1. Use keys
and
to select the field you wish to change, then use the number
keys (
, etc.) to edit the number.
or
Use keys
and
to increase or decrease the number.
2. Press
to confirm and exit.
The following table shows the voice-message sequence in accordance with the
previously mentioned parameters and options.
Note
If an event is associated with the “Automatic dialer”, the “Type Message” option refers to
messages 261 to 312, that is to say, the messages containing the event descriptions (event
types).
Options
To be activated by keys
and
:
Events
Activation
Restoral
Zone alarm
Panel T01
Panel T02
Panel T03
PROGRAMMING
Walk test
Telephone
Events
Events
Zone alarm
Terminal tamper
Partition alarm
Table 46:
Event-related messages
“Automatic dialer”
enabled
“Automatic dialer”
disabled
Message type
Plays the message relating to the event type (e.g. “zone
alarm”, “Mains failure”)
This message should not be changed.
You can select any message from 1 to 219
Message A
Blank message, editable
Message B
Contains event details, for events which are not distinctive
(e.g. the “zone alarm” event indicates the zone concerned).
Event Activation
Sequence
1.
Message type + 260
2.
Message A
3.
Message B
4.
“Location” (244)
1.
Message type
2.
Message B
3.
“Location” (244)
Sequence in the
event of Restoral
1.
“Restoral” (97)
2.
Message type
3.
Message A
4.
Message B
5.
“Location” (244)
1.
Message A
2.
Message B
3.
“Location” (244)
Table 47:
Event options
Option
If enabled
If disabled
Event ON to log
When the event occurs, it will be saved to the events log.
When the event occurs, it will not be saved to the events
log.
Event OFF to log
When the event clears, it will be saved to the events log.
When the event clears, it will not be saved to the events
log.
StartPeriodicEv.
When the event occurs, the system will generate Periodic
event number 1.
Silent event
If the event occurs, the system will generate silent calls
which will not be signaled on the keypads.
If the event occurs, the system will generate calls which
will be signaled on the keypads.