Installation and programming manual
Options and programming methods
73
Entry time 2
This is the second Entry time (delay).
Pre-arm time
This is the period (expressed in minutes) before an automatic arming operation (see
“info” box).
In order to comply with EN50131 instructions, the “Pre-arm” time must be set at a
value that is not “0”.
Patrol time
An “Inspection” period (expressed in minutes) which allows patrol-key/code holders
(security staff, night watchmen, etc.) to check the premises (see “info” box ).
All the above-mentioned “times” can be programmed as follows:
1. Use keys
and
to choose whether to indicate the time in seconds or
minutes (see note opposite).
2. Use keys
and
to select the field you wish to change, then use the number
keys (
, etc.) to edit the number.
or
Use keys
and
to increase or decrease the number.
3. Press
to confirm and exit.
Timers
Select the timer you wish to associate with the “auto-am” operations.
Note
Remember to enable auto-arm partition in the section:
User menu
,
Activations
.
Forced auto-arm operations may occur, generated by events active at the time of the
auto-arm operation.
Options
•
Auto-resetMemory -
if enabled by means of the
key, each partition arming
operation will reset the partition alarm/tamper memory automatically.
•
Auto-arm STAYmode
- if enabled by means of the
key, the partition will arm
in Stay mode at the pre-set auto-arm time. If disabled by means of the
key,
the partition will arm in Away mode at the pre-set auto-arm time.
•
StopTelOn Disarm
- if enabled, the call queue will clear when the partition disarms.
Via PC
Select an item from “SmartLiving System - Partitions” from the tree menu on the left,
then go to the “Parameters settings” template on the right.
6-14
User Codes
This programming section deals with the user code options/parameters.
The user code PINs must comprise 4, 5 or 6 digits. The PIN of user code n. 1 is “0001”
at default. The PINs of the successive user codes are “0002”, “0003”, etc.
Via Keypad
1. Accessing the" Codes” section:
Type-in Code
(Installer PIN)
, PROGRAMMING Codes
.
2. Use
and
to select the code then press
.
Description
This is an editable programming field for the code user's name.
Partitions
Select the partitions the user code is assigned to. Press
, to enable the partition
and
to disable it.
Options
Use
and
to enable/disable the code options.
If this value is
expressed in
minutes, there is an
error margin of 1
minute (for example, if you
set 5 minutes, the period can
vary between 4 and 5
minutes).
PROGRAMMING
Timers
Partitions
Codes
PROGRAMM.CODES
CODE 001
CODE 002
CODE 003