52
Options and programming methods
Confirm with *
The control panel will consider the voice call successful when the call
recipient presses “
*
” on their telephone keypad.
The control panel will consider the voice call
successful as soon as it starts the voice
message.
NoUserTamp.reset
No user will be allowed to delete of the following events:
•
terminal tamper
•
control panel open-tamper
•
control panel dislodgement-tamper
•
peripheral tamper
•
peripheral loss
•
false key
Encrypt data
The control panel will encrypt data via LAN (for SmartLAN/SI only).
Instant restoral
The restoral of the magnetic reed sensor in Air2-MC100 and Air2-
MC200 wireless detectors will be signaled instantly.
The restoral of the magnetic reed sensor in
wireless detectors will be signalled with a delay
of up to 10 seconds (maximum).
Teleserv. hidden
The
symbol will not be shown on the keypad display.
If Teleservice is enabled, the
symbol will be
shown on the keypad display.
LockInstall.Code
After hard reset (refer to
paragraph 6-25 Default settings
), all the
control panel parameters with the exception of the installer PIN will
reset to the factory default settings.
After hard reset (refer to ), all the control panel
parameters including the installer PIN will reset
to the factory default settings (installer PIN
default is 9999).
50131ReaderLedOFF
If there are no keys present at the reader, the LEDs on the nBy readers
will be Off. If a key is waved across the reader, the status will be
indicated on the LEDs for 30 seconds before switching Off again.
During this 30 second phase, the user can hold the key in the vicinity of
the reader and select the desired shortcut indicated by LEDs.
The reader LEDs indicate the related status.
50131StatHidden
The status of the partitions will be hidden.
If a valid code is entered
at a keypad, the real-time status will be indicated on the keypad con-
cerned for 30 seconds.
If the partitions are armed, the status of the system will be hidden
from non-authorized users.
•
Red keypad LED Off
•
Yellow keypad LED Off
•
Green keypad LED On solid
•
Status icons not present
•
Alarm and Tamper memory hidden
•
If a particular event occurs more than 5 times when the
partitions are armed, it will not be signaled as having
occurred more than 5 times. This is due to the limitation
placed on the counter of each event. The counters will reset
to zero each time all the partitions are disarmed.
If the partitions are DISARMED:
•
The LEDs will function normally.
•
Status icons present
•
Alarm and Tamper memory visible
The keypad will show the real-time status of the
system at all times, regardless of the status of
its partitions.
50131IconsHidden
If partitions are armed, the status icons will not be shown on the
second line on the keypad, thus non-authorized users will be unable to
view the respective conditions on the system.
If a valid code is entered at a keypad, the status of the icons will be
shown for 30 seconds.
The keypad will show the real-time status of the icons when all the
keypad partitions are disarmed.
The keypad will show the real-time status of the
icons at all times, regardless of the status of its
partitions.
50131AlarDelayed
If an instant-zone alarm occurs on a partition while entry time is running,
the associated actions (calls, output activation, save to log, etc.) will not
be generated until 30 seconds after the expiry of the entry time.
If the partition (or partitions) are disarmed during this period, the
associated actions will not be generated, however, the keypads will
indicate the violation of the instant zone.
If an instant-zone alarm occurs on a partition
while entry time is running, the associated
actions (calls, output activation, save to log,
etc.) will be activated instantly.
50131WarnLedMem
If the control panel detects a fault, the yellow LED on the keypads will
go On and will remain On even after the fault clears.
To switch the yellow LED Off, clear all activating causes and reset the
partition.
If the control panel detects a fault, the yellow
LED on the keypads will go On and will go Off
automatically when the fault clears.
DayLightSav.time
The control panel clock will go forward 1 hour at 2:00 am on the first
Sunday in October and go back 1 hour at 3:00 am on the first Sunday
in April
No automatic clock forward/back operations.
NoStringsSiaProt
The descriptive strings will not be sent in SIA reporting format.
The descriptive strings will be sent in SIA
reporting format.
AllSiaIP OnPerEv
The control panel will send calls to all SIA-IP numbers programmed for
the “Periodic event” (activation and restoral).
InvertCONTACT-ID
Partition arming events using CONTACT-ID reporting format will send
the "New event/Event activation" code when the partition is armed and
the "Event ended/Event restore" when the partition is disarmed.
Partition arming events using CONTACT-ID
reporting format will send the "New event/Event
activation" code when the partition is disarmed
and the "Event ended/Event restore" when the
partition is armed.
Table 42:
Panel options
Option
If enabled
If disabled