notE 5.
These instructions cover
the programming of AutoTimer1.
The programming for AutoTimers
2 to 8 is identical but with a different
set of option numbers. See the
Options Summary on page 92 for a
full list of programming options for
each AutoTimer.
hAnDy hint.
There are two ways to turn outputs
on by AutoTimer - depending on
how long the AUX output is to stay
on.
1. If the ON period is less than 20
seconds then the Pulse Output
option can be used to get timing
periods measured in seconds.
This method only requires one
AutoTimer to be programmed.
2. For longer periods (up to a
week), a pair of AutoTimers can be
used - one to turn the AUX ON &
the other to turn it OFF.
P350 - P354E
AUtotimEr1
/ AutoTimers 2-8
NOTE 5
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
none
rELAtED oPtions
P121E Enable AUX1 for AutoTimers
P122E Enable AUX2 for AutoTimers
P123E Enable AUX3 for AutoTimers
P124E Enable AUX4 for AutoTimers
P145E AUX1 Pulse Time.
P146E AUX2 Pulse Time.
P147E AUX3 Pulse Time.
P148E AUX4 Pulse Time.
P390E AutoTime Warning.
P392E Enable AutoTime User Codes
P202E - P256E Extra Option 9. Enable
user codes for AutoTime.
notE 1.
Do not use the same
AutoTimer to enable and disable user
codes. For example, use AutoTimer1
to set the Code Enable time and
AutoTimer2 to set the Code Disable
Time.
The user codes must also be enabled
for AutoTime using Extra Options for
user codes.
notE 2.
If Open/Closing reports are
enabled a Closing Extended report
(Contact ID 464) is sent to the control
room.
notE 3.
If Open/Closing reports are
programmed, user Codes 91 to 98 are
used to identify AutoTIME arming and
disarming. AutoTime1 is code 91 then
consecutively through to AutoTIME 8 is
code 98.
notE 4.
Note that each AutoTimer
controls different AUX outputs.
stEP 1
Set the the Time and Day Of The Week at which AutoTimer1 will activate.
KPX+
PxxxE [New Value] E
NAVIGATOR
PxxxE > [New Value] E
SMS*
P[MasterCode]E P[InstallerCode]E PxxxE [NewValue] E
Or use
NessXCEL
app
P350E
AutoTimer1 Minutes. Enter a value between 00 and 59.
P351E
AutoTimer1 Hours. Enter a value between 00 and 23. (00 = Midnight).
P352E
AutoTimer1 Day. Enter values between 1 and 7. (1E=Sunday). If the AutoTimer event is
intended to take place every day, then enable all days, 1E-7E.
stEP 2
Set the Actions which will take place on the Time and Day set above.
KPX+
PxxxE xE to enable/disable an option as required
NAVIGATOR
PxxxE > enable/disable an option as required
SMS*
P[MasterCode]E P[InstallerCode]E P392E 1E as required
Or use
NessXCEL
app
P353E
or
P354E
1E-8E
to turn an option ON or OFF. Multiple options can be selected.
TO ENABLE AUTO-ARMING
P353E 1E Area1 Arm.
Arms Area1 at the time & day set by AutoTimer1.
P353E 2E Area2 Arm.
Arms Area2 at the time & day set by AutoTimer1.
P353E 3E home Arm.
Arms Home Mode at the time & day set by AutoTimer1.
Note. Option 3E enables Home Arm for AutoTimers 1 to 6 but enables Day Mode Arm for AutoTimers 7
and 8.
TO ENABLE/DISABLE USER CODES By AUTOTIMER
notE 1
P353E 4E Code Enable.
User Codes enabled for AutoTime become active from the time set above.
CODE ENABLE/DISABLE allows a period to be set on selected days of the week during which selected
user codes can be used. Outside this period the codes will not work.
P353E 5E Code Disable.
User Codes enabled for AutoTime are disabled at the time set above.
TO ENABLE PRE-EVENT WARNING BEEPS
P353E 6E keypad beeps.
Turn this option on to enable the AutoTimer Warning (continuous slow
beeps). The keypad/s will beep to warn that this AutoTimer is about to begin. Keypad beeps begin xx
minutes before the AutoTimer is due to start as set by option P390E.
1. To
silence the beeps
during the warning period. Pressing any key on the keypad will stop the
beeps on the keypad (and the Reset output) and then start again for the final minute with a slightly
faster beep.
2. To
delay the Autotime event
, enter a valid user code on its own. (The user code must be
assigned to an Area to work). This will turn off the warning beeps and the Auto Arm for 1 hour - when
the warning process will start again.
P353E 7E reset output beeps.
If 6E is ON, then this option also beeps the RESET output for a much
louder AutoTimer warning if required.
P353E 8E Enable Autotimer Extension.
This allows the AutoTIME Arming
NOTE 2
, Code Enable &
Disable and the Aux3, Aux4 actions to be delayed by entering a USER code during the Warning period.
TO ENABLE AUTO-DISARMING FOR EACH AREA
NOTE 3
P354E 1E Area1 Disarm.
Disarms Area1 at the time & day set by AutoTimer1.
P354E 2E Area2 Disarm.
Disarms Area2 at the time & day set by AutoTimer1.
P354E 3E home Disarm.
Disarms Home Mode at the time & day set by AutoTimer1.
P354E 4E
[not used]
TO CONTROL OUTPUTS By AUTOTIMER
NOTE 4 & NOTE 5
These AUX actions will take place at the time & day set by AutoTimer1.
P354E 5E AUx1 toggle.
Changes the current state of the AUX1 output. If ON then it will turn OFF and
if OFF will turn ON.
P354E 6E AUx1 Pulse.
Turns on the AUX1 output for a time period set P145E.
P354E 7E AUx2 toggle.
Changes the current state of the AUX2 output. If ON then it will turn OFF and
if OFF will turn ON.
P354E 8E AUx2 Pulse.
Turns on the AUX2 output for a time period set P146E.
Note. AUX outputs must be enabled for control by AutoTimers at options P121E-P124E.
* SMS programming shows the full SMS string to send. KPX+ and
NAVIGATOR programming assumes the panel is already in program mode.
76
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
76
AUtomAtion
FEAtUrEs
Содержание D16XCEL
Страница 96: ......