P51E
homE ZonEs
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
all OFF: No Home zones.
notEs
By default, all Home zones have Entry
Delay2, see P64E 3E. If this option is off
Home zones have normal entry delay
attributes set by options P40E–P42E.
rELAtED oPtions
P63e
Home Mode output mapping.
P64e 1e
Brief Home alarm.
P64e 3e
Home zones have Entry Delay2.
P69e 3e
Quiet Home siren.
P69e 5e
Radio Key ON or OFF button
arms Home Mode.
P120e 2e
Home arm chirps by radio key.
P120e 3e
Radio Key AUX button arms
Home mode.
P120e 6e
Smart Beeps for Home and
Day zones.
Home zones allow you to Arm selected zones while others are ignored. Typically used for
perimeter zones such as windows and doors while you are at home.
For example: upstairs zones are Disarmed while downstairs zones are Armed in Home
mode.
KPX+
P51E [Zone Number] E to enable/disable zones
NAVIGATOR
P51E > Select zones
SMS*
P[MasterCode]E P[InstallerCode]E P51E [Zone Number] E
Or use
NessXCEL
app
NOTE: Zones selected to Report Zone Alarms (P74E) will by default report alarms in Home
Mode, (if the dialler is enabled).
The Brief Home Alarm option P64E 1E, when enabled, prevents Home alarms from
reporting.
See page 29 for Home Mode operation.
P52E
24hr ZonEs
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
All OFF: No 24hr zones.
notEs
• The Tamper input is always a 24hr
zone.
• For silent 24hr zones, deselect the
zone/s from options P54E-P57E (Reset,
Strobe, Sonalert & Siren).
• To change a 24hr zone to any other
zone type, the zone must also be re-
assigned to an AREA (P45E or P46E).
24hr Zones operate at all times regardless of the mode of panel operation, i.e. Armed,
Disarmed or Home Monitor. When alarmed, these zones will activate assigned outputs
immediately. To reset those alarms a valid user code must be entered.
Selecting a zone as 24hr will override any other zone type setting such as Instant, Delayed
or Handover. 24hr zones are independent of Area operation. All other zone types must be
assigned to at least one Area to become active.
KPX+
P52E [Zone Number] E to enable/disable zones
NAVIGATOR
P52E > Select zones
SMS*
P[MasterCode]E P[InstallerCode]E P52E [Zone Number] E
Or use
NessXCEL
app
P53E
DAy ZonEs
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
All OFF: No Day zones.
notEs
Typical uses For Day Zones, Instant
alert when a delivery door is opened,
doorway alert for a shop.
rELAtED oPtions
P63e 5e-8e
Day zone output mapping.
P64e 2e
Brief Day Mode alarm.
P120e 6e
Smart Beeps for Home and
Day zones.
Day Zones operate when the panel is fully disarmed, i.e. when Area 1, Area 2 and Home
are all off. When alarmed, these zones will activate their assigned outputs instantly.
The outputs mapped to the Day Zone will turn on while the zone is unsealed. Turn P64E 2E
on, to limit Day Zone alarms to 2 seconds.
Also see Temporary Day Zones feature (page 29) which allows day mode to be easily
enabled/disabled and day zones added/removed by the user from any keypad.
KPX+
P53E [Zone Number] E to enable/disable zones
NAVIGATOR
P53E > Select zones
SMS*
P[MasterCode]E P[InstallerCode]E P53E [Zone Number] E
Or use
NessXCEL
app
See page 29 for information about TEMPORARy DAy ZONES
* SMS programming shows the full SMS string to send. KPX+ and
NAVIGATOR programming assumes the panel is already in program mode.
30
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
P r o g r A m m i n g
Содержание D16XCEL
Страница 96: ......