Option No.
Description
Default
P69E
1E
Flash strobe on medical alert
OFF
2E
[not used]
OFF
3E
Quiet Home Siren
OFF
4E
6 beeps on Arming
OFF
5E
Home arm by radio key ON/OFF
OFF
6E
Disable Mains Fail Alarm
OFF
7E
Exit BEEPS - Full Arm
OFF
8E
Exit BEEPS - Home Mode
OFF
P69E 1E
FLAsh strobE on mEDiCAL ALArm
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
OFF
This option enables the strobe output when a medical alarm is triggered. This is to make
the house visible to the ambulance. The strobe will reset after 72 hours or when a valid
code is entered.
KPX+
P69E 1E to enable/disable the option
NAVIGATOR
P69E > enable/disable 1E
SMS*
P[MasterCode]E P[InstallerCode]E P69E 1E
Or use
NessXCEL
app
P69E 3E
QUiEt homE sirEn
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
OFF: Normal siren sound in Home
Mode.
notEs
This does not affect the RESET output.
This option selects the ‘Quiet Siren’ sound in Home Mode. The Quiet Siren sound is a
continuous “beep beep beep” sound rather than the normal siren sound.
KPX+
P69E 3E to enable/disable the option
NAVIGATOR
P69E > enable/disable 3E
SMS*
P[MasterCode]E P[InstallerCode]E P69E 3E
Or use
NessXCEL
app
P69E 4E
6 bEEPs on Arming
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
OFF: Keypad gives 3 beeps on Arming.
notEs
The keypad beeps on Arm/Disarm
when Arming/Disarming by keypad,
keyswitch or by Radio Key.
Normally the keypad/s onboard sonalert/beeper gives 3 beeps when the panel is armed.
Turning this option ON will give 6 keypad beeps when Arming.
KPX+
P69E 4E to enable/disable the option
NAVIGATOR
P69E > enable/disable 4E
SMS*
P[MasterCode]E P[InstallerCode]E P69E 4E
Or use
NessXCEL
app
* SMS programming shows the full SMS string to send. KPX+ and
NAVIGATOR programming assumes the panel is already in program mode.
44
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
P r o g r A m m i n g
Содержание D16XCEL