oPErAtion by sms
Operation by SMS messaging uses simple abbreviations for common commands as
per the table on this page.
SUMMARy OF SMS COMMANDS
The following examples use the default Master Code of 123 just as an example.
Substitute your own valid user code/s in operation.
OPERATION
SMS TO THE PANEL
SMS REPLy
ARM
A123E
A123E ACK
DISARM
123E
123E ACK
HOME mode
H123E
H123E ACK
EXCLUDE zones
(Example zones 4 & 5)
X123E4E5E
X123E ACK 4E ACK 5E
ACK E ACK
View MEMORy
(Specify the number of
events to read, eg, last
3 events, most recent
first)
M123E 3E
Event memory report
Area 1 Close User 1 Thu 6 Sep
2018 4:01pm
Radio Detector Low Battery
Zone 5 Thu 6 Sep 2018 4:05pm
Area 1 Open User 1 Thu 6 Sep
2018 4:15pm
FIRE alarm
1
(Triggers the Fire
Alarm, if enabled)
F123E
F123E ACK
MEDICAL alarm
2
(Triggers the Medical
Alarm, if enabled)
D123E
D123E ACK
PANIC alarm
3
(Triggers the Panic
Alarm, if enabled)
S123E
S123E ACK
Turn ON AUX 1
Turn OFF AUX 1
Turn ON AUX 2
Turn OFF AUX 2
Same procedure
for all eight Aux
outputs.
123E11ON
123E11OFF
123E22ON
123E22OFF
123E ACK 11* ACK
123E ACK 11# ACK
123E ACK 22* ACK
123E ACK 22# ACK
1
The FIRE alarm sounds the siren using the FIRE siren sound and sends a fire report if
programmed.
2
The MEDICAL alarm triggers the strobe light if programmed and sends a medical report if
programmed.
3
The PANIC alarm sounds the sirens and strobe if programmed.
Related options for Fire and Medical P75E, P77E, P191E, P193E, P161E, P126E 2E 3E, P69E 1E
Related options for Panic P61E 5E~8E
SMS COMMANDS
CommAnD oPErAtion
A
ARM
H
HOME
X
EXCLUDE
M
MEMORy
P
PROGRAM
1
E
ENTER
F
FIRE
D
MEDICAL
S
PANIC
11E ~ 88E
OPERATE AUX
OUTPUTS
T
TEXT
2
1
See page 17 for detail
2
See page 21-22 for detail
14
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
Содержание D16XCEL