Option No.
Description
Default
P68E
1E
Double Press Radio Panic
OFF
2E
Auto Re-Arm
OFF
3E
Long Radio Message
ON
4E
"OK/READy" Display
OFF
5E
Radio Arming “unsealed” warning
OFF
6E
24hr Zone Fire Siren sound
OFF
7E
Single Shot strobe on Arm by R/Key
OFF
8E
Quiet chirps on radio Arm/Disarm
OFF
P68E 1E
DoUbLE PrEss rADio PAniC
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
OFF: Single Press Radio Panic.
Setting this option ON enables Double Press Panic for Ness Radio Keys, if fitted. The panel
will look for two radio Panic signals in a row to sound the Panic alarm.
oPErAtion.
On the Radio Key, press and hold Panic until the transmit LED turns on. Wait
until the LED turns off then release the Panic button and immediately press and hold again
until the transmit LED turns on a second time.
This requirement meets regulations in some states of Australia.
KPX+
P68E 1E to enable/disable the option
NAVIGATOR
P68E > enable/disable 1E
SMS*
P[MasterCode]E P[InstallerCode]E P68E 1E
Or use
NessXCEL
app
P68E 2E
AUto rE-Arm
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
OFF: Auto Re-Arm disabled.
notEs
• Auto re-arm will not take place if
the panel is disarmed during the exit
delay time. This allows you to disarm
immediately if you change your mind
about leaving the premises.
• Auto re-arm operates independently
on both Areas 1 and 2.
rELAtED oPtions
P26E Entry Delay Time1 sets the "time
before re-arming".
For example, say P26E is 30sec, if you
disarm the panel and do not enter the
premises, then the panel will Auto Re-
arm in 30 seconds.
When this option is enabled, Auto Re-Arm checks that you have entered the premises after
disarming.
After disarming, the panel will wait for the duration set for Entry Delay. If all zones remain
sealed the panel will re-arm. This is most useful when used with radio keys where the OFF
button might be accidentally pressed after you have armed and are leaving the premises.
KPX+
P68E 2E to enable/disable the option
NAVIGATOR
P68E > enable/disable 2E
SMS*
P[MasterCode]E P[InstallerCode]E P68E 2E
Or use
NessXCEL
app
P68E 3E
Long rADio mEssAgE
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
ON: Long Radio Message.
notEs
Some models of Ness detectors and
radio keys without encryption will not
work with this setting on.
if a radio device is not recognised
when you try to enrol it on this
control panel, turn this option off then
attempt to enrol the radio device.
Setting this option ON enables Long Radio Message for Radio Keys and Radio Devices.
Radio detectors will now need the encryption link turned on. Enabling Long Radio Message
gives greater protection against coding clashes with third party radio signals.
KPX+
P68E 3E to enable/disable the option
NAVIGATOR
P68E > enable/disable 3E
SMS*
P[MasterCode]E P[InstallerCode]E P68E 3E
Or use
NessXCEL
app
* SMS programming shows the full SMS string to send. KPX+ and
NAVIGATOR programming assumes the panel is already in program mode.
42
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
P r o g r A m m i n g
Содержание D16XCEL