AUx4
OUTPUT OPTIONS
P144E
EnhAnCED AUx4 oPtions
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
All off.
notEs
Any or all options may be selected on.
The P144E enhanced AUX4 options work along with P124E and AutoTimers to provide
multiple choices of events and alarms to control AUX4.
KPX+
P144E 1E - 8E to enable/disable the option as required
NAVIGATOR
P144E > enable/disable 1E - 8E as required
SMS*
P[MasterCode]E P[InstallerCode]E P144E [1E -8E] as required
Or use
NessXCEL
app
P144E 1E
ArEA1 ArmED to AUx4
Turns on AUX4 while Area 1 is armed.
P144E 2E
ArEA2 ArmED to AUx4
Turns on AUX4 while Area 2 is armed.
P144E 3E
homE ArmED to AUx4
Turns on AUX4 while armed in Home mode.
P144E 4E
kEyPAD toggLE AUx4
When this option is on,
AUX4 is turned ON or PULSED with the keypress 44* (* = Left hand STAR button).
AUX4 is turned OFF with the keypress 44# (# = Right hand STAR button).
P144E 8E
PULsE AUx4
rELAtED oPtions
P148E, AUX4 Pulse Time.
P144E 4E must also be on for this
option to work
This option converts the P144E 1E, 2E, 3E, 4E, 5E options into a pulsed AUX4 output.
AUX4 is pulsed on for the time set in P148E.
Option No.
Description
Default
Note
P148E
AUX4 TIMER
20 sec
1 to 99 seconds
P148E
AUx4 timEr
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
20 sec.
rELAtED oPtions
P144E 8E
Sets the length of pulse time for the AUX4 output when the P144E 8E option is selected.
Select 1 to 99 seconds.
KPX+
P148E [New Time] E
NAVIGATOR
P148E > [New Time] E
SMS*
P[MasterCode]E P[InstallerCode]E P148E [NewTime] E
Or use
NessXCEL
app
Aux4 driving the Quantum Sonic onboard siren as an
extension sonalert.
Aux4 driving an extension sonalert. See P124E 2E.
Use 106-013 Relay Board or 100-699 or 106-011 Output Expander
WIRING EXAMPLES
70