Use one of these Quick Start programming summaries for fast setup of your control panel with typical Local, SMS Monitored or
Central Station Monitored options.
QUiCk stArt 1 - LoCAL systEm, simPLy ProgrAm A UsEr CoDE
STEP KPX+ or SATURN KP
DESCRIPTION
COMMENT
1
P 1 2 3 E
Enters User Program Mode.
PROG icon will turn on. (Default User Code is 123).
2
P 2 0 1 E
Selects the option for User Code 1.
The existing code will be displayed.
3
_ _ _ _ E
Enter your new PIN code followed by E. Keypad codes can be 3 to 6 digits in length.
4
_ _ _ _ E
Enter your new PIN code again.
The new code will be displayed.
5
P E
To exit program mode.
PROG icon will turn off.
QUiCk stArt 2 - sms sELF-monitoring
STEP KPX+ or SATURN KP
DESCRIPTION
COMMENT
1
P 1 2 3 E
Enters User Program Mode.
PROG icon will turn on. (Default User Code is 123).
2
P 0 0 0 0 0 0 E
Enters Installer Program Mode.
PROG icon will flash. (Default Installer Code is 000000).
3
P 2 0 1 E
Selects the option for User Code 1.
The existing code will be displayed.
4
_ _ _ _ E
Enter your new PIN code followed by E. Keypad codes can be 3 to 6 digits in length.
5
_ _ _ _ E
Enter your new PIN code again.
The new code will be displayed.
6
P 1 8 0 E
Enter a mobile phone number followed
by E
This mobile phone number will receive alarm reports, if enabled.
Up to 10 mobile numbers can be programmed, see P180E to
P189E. See P190E to P194E to enable/disable various SMS
alarm reports.
7
P E
To exit program mode.
PROG icon will turn off.
QUiCk stArt 3 - CEntrAL stAtion monitoring
STEP KPX+ or SATURN KP
DESCRIPTION
COMMENT
1
P 1 2 3 E
Enters User Program Mode.
PROG icon will turn on. (Default User Code is 123).
2
P 0 0 0 0 0 0 E
Enters Installer Program Mode.
PROG icon will flash. (Default Installer Code is 000000).
3
P 2 0 1 E
Selects the option for User Code 1.
The existing code will be displayed.
4
_ _ _ _ E
Enter your new PIN code followed by E.
Keypad codes can be 3 to 6 digits in length.
5
_ _ _ _ E
Enter your new PIN code again.
The new code will be displayed.
6
P 1 7 0 E
Selects the option for CID Phone No 1.
7
_ _ _ _ _ _ _ _ E
Enter the central station telephone
number followed by E
30 digits maximum.
8
P 7 2 E
Selects the option for Account No 1.
9
_ _ _ _ E
Enter the Account number followed by E 4 digits maximum. The account number is supplied by your
central monitoring station.
10
P E
To exit program mode.
PROG icon will turn off.
Quick start Programming guide
With some options U and Z
can replace E to ensure an op-
tion is ON or OFF
instead of toggled.
Example:
P39E1E toggles option 1.
P39E1U sets ON option 1.
P39E1Z sets OFF option 1.
16
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
P r o g r A m m i n g
Содержание D16XCEL
Страница 96: ......