instALLEr ProgrAm moDE
Installer Program Mode allows access to ALL
program options.
notE 1.
NessComms Direct Connect via the
serial port requires the panel to be in Installer
Program Mode.
notE 2.
The panel will remain in Installer
Program Mode until
P + E is entered by keypad.
instALLEr's PoWEr tiP
All inputs are disabled while the panel is in
Installer Program Mode. This handy feature
allows you to work on the system without
triggering 24 hour zones such as tamper
inputs.
UsEr ProgrAm moDE
User Program Mode allows the owner to program:
• All User Codes
• Entry Exit Times
• SMS Telephone numbers
• Real Time Clock settings
Note: The panel will automatically drop out of
User Program Mode to Operating Mode if no
keypad buttons are pressed for 4 minutes.
hoW to EntEr ProgrAm moDE
METHOD 1.
FIRST TIME PROGRAMMING – FROM POWER UP
1. Power-up with the J1 PROG/TAMP link OFF.
Replace the PROG/TAMP link (or Box Tamper lead) after
programming. The link must be on in normal operating mode.
METHOD 2.
USING ANy KEyPAD TO ENTER PROGRAM MODE
The panel must be Disarmed.
1. Press P
+
[MasterCode]
+
E
This is User Program Mode (PROG icon is ON).
Various user options can be programmed in this mode.
2. Press P
+
[InstallerCode]
+
E
This is Installer Program Mode (PROG icon is FLASHING).
All program options can be programmed in this mode.
hoW to Exit ProgrAm moDE
Press
P
+
E
Exits directly to Operating Mode (PROG icon is OFF).
FACtory DEFAULts
Master Code: 123
Installer Code: 000000
15
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
P r o g r A m m i n g
SPECIAL FUNCTION
PROGRAM
MODE
KEyPRESS
SEND DIALLER TEST REPORT
Send a Dialler Test Report to the telephone number programmed at P170E.
USER
P 66666666 E
(eight 6's)
SIREN TEST
Turn the Siren, Reset and Strobe Outputs On. Pressing P E will stop the Siren Test (and also exits
Program Mode).
USER or
INSTALLER
P 77777777 E
(eight 7's)
PANEL RESET
This function resets the microprocessor. The effect is the same as powering down and powering up
again. INSTALLER'S TIP: Use P88888888E prior to powering down for a short time. This will save the
current Time Before Next Test Call and the Real Time Clock into permanent memory. On power up
these times will be restored.
USER or
INSTALLER
P 88888888 E
(eight 8's)
DISPLAy SOFTWARE VERSION
This function displays the panel software version when in program mode. Displayed in decimal
format by the zone LEDs. Example, version V6.1 is displayed by flashing 6 followed by 1.
USER or
INSTALLER
P 99999999 E
(eight 9's)