P120E 5E
kEysWitCh Arm onLy
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
OFF
rELAtED oPtions
P120E 1E Latched Keyswitch.
P60E 2E, 3E Keyswitch options
Converts the use of keyswitch operation using P60E 2E and 3E to only arm either from
Area or Home mode. Keyswitch operation must first be enabled using options P60E 2E,
3E, page 33.
KPX+
P120E 5E to enable/disable the option
NAVIGATOR
P120E > enable/disable 5E
SMS*
P[MasterCode]E P[InstallerCode]E P120E 5E
Or use
NessXCEL
app
P120E 6E
smArt bEEPs
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
OFF
notEs
• The zone causing the event is saved and
can be identified by viewing MEMORy.
Only one of the same consecutive zone
warnings is saved, although the MEMORy
display will flash each time (unless
disabled by P94E option).
• Smart Beeps work in addition to any
other outputs mapped to Home and
Day alarms, as programmed by options
P63E 1E–8E.
• Smart Beeps work in conjunction with
any other Home and Day mode outputs,
(as set by options P63E 1E–8E).
Smart Beeps are available in Brief Home or Brief Day mode to identify zones by keypad
beeps.
When a Home zone or Day zone is triggered, the zone number is slowly beeped out,
followed by 2 seconds of silence. This is repeated 3 times and can be stopped by another
beep (such as keypress).
If the zone has entry delay you will hear the Smart Beeps sequence once when the zone is
triggered and again at the end of entry delay. If Entry Beeps are disabled (P60E 1E), Smart
Beeps will only be heard at the end of entry delay.
Smart Beeps use the keypad/s onboard sonalert, so option P63E 3E and/or 7E must be on
to enable the sonalert output for Home alarms and Day alarms.
KPX+
P120E 6E to enable/disable the option
NAVIGATOR
P120E > enable/disable 6E
SMS*
P[MasterCode]E P[InstallerCode]E P120E 6E
Or use
NessXCEL
app
P120E 7E
Entry DELAy ExtEnDEr
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
OFF
rELAtED oPtions
P26E Entry Delay Time1.
When enabled, this option increases the Entry Delay Time1 by a factor of 10. Example, if
P26E is programmed for 30 sec, it becomes 300 sec. (Entry Delay Time2 is unaffected).
KPX+
P120E 7E to enable/disable the option
NAVIGATOR
P120E > enable/disable 7E
SMS*
P[MasterCode]E P[InstallerCode]E P120E 7E
Or use
NessXCEL
app
P120E 8E
ArEA2 DisArm by kEysWitCh ALLoWED
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
OFF
rELAtED oPtions
P60E 2E, 3E. P120E 1E, 4E, 5E
This option allows the keyswitch (if enabled) to disarm Area2. Note, the keyswitch cannot
arm Area2, only disarm. Though it can both arm & disarm Area1.
KPX+
P120E 8E to enable/disable the option
NAVIGATOR
P120E > enable/disable 8E
SMS*
P[MasterCode]E P[InstallerCode]E P120E 8E
Or use
NessXCEL
app
* SMS programming shows the full SMS string to send. KPX+ and
NAVIGATOR programming assumes the panel is already in program mode.
62
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
P r o g r A m m i n g
Содержание D16XCEL