Troubleshooting 8-5
On-screen error message
Action
0B93 BMC SDR Repository empty.
Power off and reboot the CPU blade. If
the error persists, contact your service
representative.
0B94 IPMB signal lines do not respond.
Access to SMC via IPMB is unavailable.
This is not a fatal error, however, power-
off and reboot the CPU blade. If the error
persists, contact your service
representative.
0B95 BMC FRU device failure.
FRU command and EMP feature are
unavailable. This is not a fatal error,
however, power-off and reboot the CPU
blade. If the error persists, contact your
service representative.
0B96 BMC SDR Repository failure.
0B97 BMC SEL device failure.
0B98 BMC RAM test error
0B99 BMC Fatal hardware error.
0B9A Management controller not responding
0B9B Private I2C bus not responding.
0B9C BMC internal exception
0B9D BMC A/D timeout error.
0B9E SDR repository corrupt.
0B9F SEL corrupt.
0BB0 SMBIOS - SROM data read error.
0BB1 SMBIOS - SROM data checksum bad.
0BD0 1st SMBus device address not acknowledged.
Power off and reboot the CPU blade. If
the error persists, contact your service
representative.
0BD1 1st SMBus device Error detected.
0BD2 1st SMBus timeout.
0BD3 2nd SMBus device address not acknowledged.
0BD4 2nd SMBus device Error detected.
0BD5 2nd SMBus timeout.
0BD3 3rd SMBus device address not acknowledged.
0BD4 3rd SMBus device Error detected.
0BD5 3rd SMBus timeout.
0BD9 4th SMBus device address not acknowledged.
0BDA 4th SMBus device Error detected.
0BDB 4th SMBus timeout.
0BDC 5th SMBus device address not acknowledged.
0BDD 5th SMBus device Error detected.
0BDE 5th SMBus timeout.
0BE8 IPMB device address not acknowledged.
0BE9 IPMB device Error detected.
0BEA IPMB timeout.
8100
Memory decreased in Size
Contact your service representative.
Содержание N8400-086F
Страница 14: ...viii This page is intentionally left blank...
Страница 44: ...2 20 General Description This page is intentionally left blank...
Страница 103: ...Installing the Operating System with Express Setup 5 31 5 Select Perform the Express setup from the Top Menu click Next...
Страница 137: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear...
Страница 152: ...6 24 Installing and Using Utilities This page is intentionally left blank...
Страница 158: ...7 6 Maintenance This page is intentionally left blank...
Страница 218: ...A 2 Specifications This page is intentionally left blank...
Страница 290: ...B 72 Installing the Operating System 4 Activate Windows The Windows activation is complete...
Страница 294: ...B 76 Installing the Operating System 3 Process Windows activation according to the following message...