104
CHAPTER 6 8-BIT TIMER/EVENT COUNTERS 50 TO 53
User’s Manual U15104EJ2V0UD
(4) 8-bit timer mode control register 53 (TMC53)
The TMC53 register is used for the following.
<1> Controlling count operation of 8-bit timer counter 53 (TM53)
<2> Selecting single mode or cascade mode
TMC53 can be set with a 1-bit or 8-bit memory manipulation instruction.
Reset input clears TMC53 to 00H.
Figure 6-8. Format of 8-Bit Timer Mode Control Register 53 (TMC53)
TCE53
Control of count operation of TM53
0
Clears counter to 0 and disables count operation (disables prescaler)
1
Starts count operation
TMC534
Selection of single mode or cascade mode
0
Single mode
1
Cascade mode (connected to lower timer (TM52))
<7>
6
5
4
3
TCE53
0
0
0
0
0
TMC534
0
2
1
0
Symbol
TMC53
Address
FF78H
After reset
00H
R/W
R/W