124
CHAPTER 8 WATCHDOG TIMER
User’s Manual U15104EJ2V0UD
(3) Oscillation stabilization time select register (OSTS)
This register is used to select the time required for oscillation to stabilize after the RESET signal has been
input or the STOP mode has been released.
This register is set with an 8-bit memory manipulation instruction.
Reset input sets OSTS to 04H. Therefore, it takes 2
17
/f
X
to release the STOP mode by RESET input.
Figure 8-4. Format of Oscillation Stabilization Time Select Register (OSTS)
OSTS2 OSTS1 OSTS0
Selection of oscillation stabilization time
0
0
0
2
12
/f
X
(910
µ
s)
0
0
1
2
14
/f
X
(3.64 ms)
0
1
0
2
15
/f
X
(7.28 ms)
0
1
1
2
16
/f
X
(14.6 ms)
1
0
0
2
17
/f
X
(29.1 ms)
Other than above
Setting prohibited
Remarks 1. f
X
: System clock oscillation frequency
2. ( ): f
X
= 4.5 MHz
Address
FFFAH
Symbol
OSTS
7
0
6
0
5
0
4
0
3
0
2
OSTS2
1
OSTS1
0
OSTS0
After reset
04H
R/W
R/W
Содержание mPD178053
Страница 2: ...2 User s Manual U15104EJ2V0UD MEMO ...