1. Setup Procedure
Express5800/R320g-E4,
R320g-M4
Installation Guide (VMware)
31
Chapter 1 Installing Operating System
5. Press the POWER switch on front panel to start the system from the CPU/IO module
1
, and perform
Steps 2-1 to 2-14 in similar way.
This is the end of steps for setting HBA configuration by using Qlogic.
Because it’s necessary to return setting,
perform next step definitely before installing VMware ESXi.
6. After configuring the settings for the CPU/IO module 1, set the CPU/IO module
0
as primary.
When the NEC logo is displayed on the screen of the display unit after the system reboots, press the
POWER switch on the front of the unit to turn off the power.
Then, disconnect all the power cords from the server.
Note
Make sure that System POWER LED is unlit before disconnecting the power cord.
7.
Connect the power cord to the server according to step 1 in this section to start the system from CPU/IO
module
0
.
8. Press the POWER switch that is located on the front side of the server.
Refer to
“1.4 Enabling Fibre Channel card”
, start BIOS Setup Utility.
Select “Boot Mode” in the Boot menu. Change to
“UEFI”
from “Legacy”.
9. Check that “Boot Mode” is
UEFI
, then select
Save changes and Power Off
in Save & Exit menu, save
parameters and exit SETUP.