2. List of Windows Event Logs
Express5800/R120e-1M, R120e-2M Maintenance Guide
142
Chapter 3 Appendix
Disk
Error
The driver detected a controller error on Device\Harddisk
X
\DR
X
.
Note
: A different number replaces
X
depending on the
connection
status of the disk.
11
Upon connecting with a USB device,
remote media,
and/or Virtual Flash USB Device
When the below values are 00 in
Details in the event logs
→
Display
, this event does not affect system operation.
<Word style>
0000: 0068030E 00000001 00000000 C004000B
0008: 00000103 00000000 00000000 002D0800
0010: 00000000 00000000 000427B7 00000000
0018: FFFFFFFF 00000006 00000040 00000000
0020: 12060000 10000008 00000000 0000003C
0028: 00000000 86BAA280 00000000 86BDB008
0030: 00000000 00000000 00000000 00000000
0038: 00000000 00000000 00000000 00000000
0040: 00000000 00000000 00000000 00000000
0048: 00000000 00000000 00000000 00000000
0050: 00000000 00000000
<Byte style>
0000: 0E 03 68 00 01 00 00 00 ..h.....
0008: 00 00 00 00 0B 00 04 C0 .......A
0010: 03 01 00 00 00 00 00 00 ........
0018: 00 00 00 00 00 08 2D 00 ......-.
0020: 00 00 00 00 00 00 00 00 ........
0028: B7 27 04 00 00 00 00 00
•
'......
0030: FF FF FF FF 06 00 00 00 yyyy....
0038: 40 00 00 00 00 00 00 00 @.......
0040: 00 00 06 12 08 00 00 10 ........
0048: 00 00 00 00 3C 00 00 00 ....<...
0050: 00 00 00 00 80 A2 BA 86 ....?
¢
o?
0058: 00 00 00 00 08 B0 BD 86 .....°??
0060: 00 00 00 00 00 00 00 00 ........
0068: 00 00 00 00 00 00 00 00 ........
0070: 00 00 00 00 00 00 00 00 ........
0078: 00 00 00 00 00 00 00 00 ........
0080: 00 00 00 00 00 00 00 00 ........
0088: 00 00 00 00 00 00 00 00
e1rexpress
Warning
Intel(R) Ethernet Server Adapter I340-T2 #xx
Network link is disconnected.
27
Upon system startup or upon applying Starter
Pack
If the message appears upon system startup or upon applying
Starter Pack, there is no problem in system operation.
megasas2
Warning
Reset to device, \Device\RaidPortX, was issued.
(The rest is skipped.)
129
When the system is used.
Retry by OS has succeeded. It is not the problem in operating the
system.
(A different number replaces X depending on the system.)
Microsoft-Windows-
Time-Service
Warning
NtpClient was unable to set a manual peer to use as a time source
because of DNS resolution error on''.
NtpClient will try again in 3473457 minutes and double the
reattempt interval thereafter.
The error was: No such host is known. (0x80072AF9)
134
Upon OS Installation
This event does not affect system operation.
IPMIDRV
Warning
The IPMI device driver attempted to communicate with the IPMI
BMC
device during normal operation.
However the communication failed due to a timeout.
You can increase the timeouts associated with the IPMI device
driver.
1004
When you operate
Windows Server 2008 R2
The above event log may be recorded. Usually, however, IPMI
command retry processing is performed, so there is no operation
problem.