1. POST Error Message
Express5800/R120e-1M, R120e-2M Maintenance Guide
130
Chapter 3 Appendix
Error Message
Cause
Solution
B272 PCI
Slot 1B - PCIe Link Speed
Error
Link Speed error was detected
on PCI Slot 1B.
B273 PCI
Slot 2B - PCIe Link Speed
Error
Link Speed error was detected
on PCI Slot 2B.
B275 PCI
Slot 1C - PCIe Link Speed
Error
Link Speed error was detected
on PCI Slot 1C.
B276 PCI
Slot 2C - PCIe Link Speed
Error
Link Speed error was detected
on PCI Slot 2C.
B277 PCI
Slot 3C - PCIe Link Speed
Error
Link Speed error was detected
on PCI Slot 3C.
B278 PCI
Slot 1D - PCIe Link Speed
Error
Link Speed error was detected
on PCI Slot 1D.
B800
DXE_PCI_BUS_OUT_OF_RESOURCES
Resources to be allocated to
PCI expansion card was
insufficient.
C000
The error occurred during
fan sensor reading.
An error was detected while
reading fan sensor.
C010
The error occurred during
temperature sensor reading
An error was detected while
reading temperature sensor.
Contact your sales representative.
C011
System Temperature out of
the range.
A temperature abnormality was
detected.
It is possible that a fan has failed or is clogged.
Contact your sales representative.
C020
The error occurred during
voltage sensor reading.
An error was detected while
reading voltage sensor.
C021
System Voltage out of the
range.
A system voltage abnormality
was detected.
C040
SROM data read error
An error was detected while
reading data on SROM.
C061
1st SMBus device Error
detected.
An error was detected on 1st
SM Bus.
C062
2nd SMBus device Error
detected.
An error was detected on 2nd
SM Bus.
C063
3rd SMBus device Error
detected.
An error was detected on 3rd
SM Bus.
C064
4th SMBus device Error
detected.
An error was detected on 4th
SM Bus.
C065
5th SMBus device Error
detected.
An error was detected on 5th
SM Bus.
C066
6th SMBus device Error
detected.
An error was detected on 6th
SM Bus.
C067
7th SMBus device Error
detected.
An error was detected on 7th
SM Bus.
C068
8th SMBus device Error
detected.
An error was detected on 8th
SM Bus.
Contact your sales representative.
C101
BMC Memory Test
Failed.
C102
BMC Firmware Code
Area CRC check Failed.
C103
BMC core hardware failure.
An error was detected on BMC.
C104 BMC
IBF or OBF check failed.
An error was detected while
accessing BMC.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
C105
BMC SEL area full.
There is not enough space to
store the system event log.
Start up Offline Tools (
Chapter 1, 9. Offline Tools
)
and delete the event logs.
C10C
BMC update firmware
corrupted.
An illegality was detected while
updating BMC firmware.
C10D Internal
Use Area of BMC FRU
corrupted.
An illegality was detected in
FRU containing the device
information.
C10E
BMC SDR Repository empty.
An error was detected on BMC
SDR.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.