1. POST Error Message
Express5800/R120e-1M, R120e-2M Maintenance Guide
128
Chapter 3 Appendix
Error Message
Cause
Solution
AE8C
CPU1_DIMM12 with error is
enabled.
An error in CPU1_DIMM12 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
AE8D
CPU2_DIMM1 with error is
enabled.
An error in CPU2_DIMM1
occurred, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
AE8E
CPU2_DIMM2 with error is
enabled.
An error in CPU2_DIMM2 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
AE8F
CPU2_DIMM3 with error is
enabled.
An error in CPU2_DIMM3 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
AE90
CPU2_DIMM4 with error is
enabled.
An error in CPU2_DIMM4 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
AE91
CPU2_DIMM5 with error is
enabled.
An error in CPU2_DIMM5 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
AE92
CPU2_DIMM6 with error is
enabled.
An error in CPU2_DIMM6 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
AE93
CPU2_DIMM7 with error is
enabled.
An error in CPU2_DIMM7 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
AE94
CPU2_DIMM8 with error is
enabled.
An error in CPU2_DIMM8 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
AE95
CPU2_DIMM9 with error is
enabled.
An error in CPU2_DIMM9 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
AE96
CPU2_DIMM10 with error is
enabled.
An error in CPU2_DIMM10 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
AE97
CPU2_DIMM11 with error is
enabled.
An error in CPU2_DIMM11 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
AE98
CPU2_DIMM12 with error is
enabled.
An error in CPU2_DIMM12 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
Contact your sales representative.
B000
Expansion ROM not
initialized
Failed to expand option ROM.
Disable expansion of option ROM of the board
that is not used for OS boot.
B001
Expansion ROM not
initialized - PCI Slot 1B
Option ROM expansion in PCI
slot 1B failed.
B002
Expansion ROM not
initialized - PCI Slot 2B
Option ROM expansion in PCI
slot 2B failed.
B003
Expansion ROM not
initialized - PCI
Slot 1C
Option ROM expansion in PCI
slot 1C failed.
B004
Expansion ROM not
initialized - PCI
Slot 2C
Option ROM expansion in PCI
slot 2C failed.
B005
Expansion ROM not
initialized - PCI
Slot 3C
Option ROM expansion in PCI
slot 3C failed.
Disable expansion of option ROM of the option
board that is not used for OS boot.
Run SETUP, and select
Advanced
→
PCI
Configuration
→
PCI Device Controller and
Option ROM Settings
→
PCIxx Slot Option
ROM
→
Disabled
. (xx: PCI slot number)