1. POST Error Message
Express5800/R120e-1M, R120e-2M Maintenance Guide
131
Chapter 3 Appendix
Error Message
Cause
Solution
C10F
IPMB signal lines do not
respond.
Failure of Satellite Management
Controller was detected.
C110
BMC FRU device failure.
An error was detected in FRU
that contains device
information.
C111 BMC
SDR Repository failure.
Failure was detected in SROM
that stores the SDR.
C112
BMC SEL device failure.
Device failure was detected in
BMC SEL.
C113
BMC RAM test error.
An error was detected in BMC
RAM.
C114
BMC Fatal hardware error.
A hardware error was detected
in BMC.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
C115 Management
controller
not responding
Management controller does
not respond.
Update the BMC firmware.
If the same error is detected repeatedly, contact
your sales representative.
C116
Private I2C bus not
responding.
Private I2C bus does not
respond.
C117
BMC internal exception
BMC internal error was
detected.
C118
BMC A/D timeout error.
BMC A/D timeout error was
detected.
C119
SDR repository corrupt.
BMC error or illegal SDR data
was detected.
C11A SEL
corrupt.
BMC error or illegal system
event log data was detected.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
C11B
BMC Mezzanine card is not
found.
BMC Mezzanine card is not
installed.
C11C
BMC Mezzanine partition is
invalid.
A format error was detected in
BMC Mezzanine card.
Contact your sales representative.
C11D
BMC is in Forced Boot Mode.
Detected that BMC is in Forced
Boot Mode.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on motherboard.
If the same error is detected repeatedly, contact
your sales representative.
C11E
Communication with BMC was
failed in previous boot
Communication with BMC was
failed in previous boot
Unplug the power cord, wait for 30 seconds, and
reboot the server. If the same error is detected
repeatedly, contact your service representative.
C11F
Backup Data of BMC Mezzanine
card has corrupted.
Inconsistency was found on
BMC mezzanine card.
Contact your service representative.
C300 Out-of-band
setup
configuration failure
An error was detected while
accessing BMC Mezzanine
card.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
C301
SDR mismatch error
Inconsistency in the hardware
information of the sensor data
record was detected
C302
Hardware configuration
error.
Illegal hardware configuration
was detected.
C303
FAN Structure ID command
error.
Illegal fan control was detected
when RAID Controller is
installed.
C304
Necessary to update SDR
Version for new RAID Card.
SDR for RAID Controller is
inappropriate.
C310 Hardware configuration of
cooling is insufficient.
Detected that cooling power is
insufficient in this hardware
configuration.
C320 Unmatched PSUs.
Unmatched power supply units
are configured.
C321 System power consumption is
out-of-range in PSUs.
System power consumption
exceeds the power output
capacity limit.
C322 No information for system
power consumption check.
No information is acquired in
checking system power
consumption.
Contact your sales representative.