1. POST Error Message
Express5800/E120f-M Maintenance Guide
139
Chapter 3 Appendix
Error Message
Cause
Solution
C300
Out-of-band setup
configuration failure
Configuration change requested by
remote terminal via network failed.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the
same error is detected repeatedly, contact
your sales representative.
C301
SDR mismatch error
Inconsistency in the hardware
information of the sensor data record
was detected
Contact your sales representative.
C302
Hardware configuration
error.
Illegal hardware configuration was
detected.
C303
FAN Structure ID command
error.
Illegal fan control was detected when
RAID Controller is installed.
C304
Necessary to update SDR
Version for new RAID Card.
SDR for RAID Controller is
inappropriate.
C320 Unmatched PSUs.
Unmatched power supply units are
configured.
C321 System power consumption is
out-of-range in PSUs.
System power consumption exceeds
the power output capacity limit.
C322 No information for system
power consumption check.
No information is acquired in checking
system power consumption.
C324
Unsupported combination of
module enclosure and server
module.
Unsupported combination of module
enclosure and server module.
The server may fail to operate correctly.
Contact your sales representative.
C325
Can't read module enclosure
FRU.
Cannot read module enclosure FRU. The chassis information may be lost, or
module is failed. Contact your sales
representative.
C501 Intel(R) Node Manager is in
Recovery Mode.
Intel Node Manager is in Recovery
Mode.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that
time, check the jumper switch setting on
motherboard. If the same error is detected
repeatedly, contact your sales
representative.