1. POST Error Message
Express5800/E120f-M Maintenance Guide
138
Chapter 3 Appendix
Error Message
Cause
Solution
C10B
BMC operational code
corrupted.
Failed to start BMC firmware.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the
same error is detected repeatedly, contact
your sales representative.
C10C
BMC update firmware
corrupted.
An illegality was detected while
updating BMC firmware.
C10D
Internal Use Area of BMC FRU
corrupted.
An illegality was detected in FRU
containing the device information.
C10E
BMC SDR Repository empty.
An error was detected on BMC SDR.
C10F
IPMB signal lines do not
respond.
Failure of Satellite Management
Controller was detected.
C110
BMC FRU device failure.
An error was detected in FRU that
contains device information.
C111
BMC SDR Repository failure.
Failure was detected in SROM that
stores the SDR.
C112
BMC SEL device failure.
Device failure was detected in BMC
SEL.
C113
BMC RAM test error.
An error was detected in BMC RAM.
C114
BMC Fatal hardware error.
A hardware error was detected in
BMC.
C115
Management controller
not responding
Management controller does not
respond.
Update the BMC firmware.
If the same error is detected repeatedly,
contact your sales representative.
C116
Private I2C bus not
responding.
Private I2C bus does not respond.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the
same error is detected repeatedly, contact
your sales representative.
C117
BMC internal exception
BMC internal error was detected.
C118
BMC A/D timeout error.
BMC A/D timeout error was detected.
C119
SDR repository corrupt.
BMC error or illegal SDR data was
detected.
C11A
SEL corrupt.
BMC error or illegal system event log
data was detected.
C11B
BMC Mezzanine card is not
found.
BMC Mezzanine card is not installed. Contact your sales representative.
C11C
BMC Mezzanine partition is
invalid.
A format error was detected in BMC
Mezzanine card.
C11D
BMC is in Forced Boot Mode.
Detected that BMC is in Forced Boot
Mode.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that
time, check the jumper switch setting on
motherboard. If the same error is detected
repeatedly, contact your sales
representative.
C11E
Communication with BMC was
failed in previous boot
Communication with BMC was failed
in previous boot
Unplug the power cord, wait for 30
seconds, and reboot the server. If the same
error is detected repeatedly, contact your
service representative.
C11F
Backup Data of BMC Mezzanine
card has corrupted.
Inconsistency was found on BMC
mezzanine card.
Contact your sales representative.
C200
The error occurred during
memory configuration check.
Memory configuration could not be
obtained.
C201
Memory Configuration change is
detected.
The memory configuration has
changed since the previous startup.
When
Check previous system Config
is
enabled in
Server
menu of the setup, this
message appears if the configuration was
changed since the previous startup. If this
message appears even when no
configuration change has been made,
contact your service representative.
C202
The error occurred during CPU
configuration check.
The CPU information could not be
obtained.
Contact your service representative.
C203
CPU Configuration change is
detected.
The CPU configuration has changed
since the previous startup.
When
Check previous system Config
is
enabled in
Server
menu of the setup, this
message appears if the configuration was
changed since the previous startup. If this
message appears even when no
configuration change has been made,
contact your service representative.