1. POST Error Message
Express5800/E120f-M Maintenance Guide
137
Chapter 3 Appendix
Error Message
Cause
Solution
B224
Onboard LAN 4 - PCIe Link
Width Error
Link Width error was detected on
onboard LAN4.
Contact your sales representative.
B231
PCI Slot 1 - PCIe Link Width
Error
A Link Width error was detected in
PCI Slot 1.
B232
PCI Slot 2 - PCIe Link Width
Error
A Link Width error was detected in
PCI Slot 2.
B261
Onboard LAN 1 - PCIe Link
Speed Error
Link Speed error was detected on
onboard LAN1.
B262
Onboard LAN 2 - PCIe Link
Speed Error
Link Speed error was detected on
onboard LAN2.
B263
Onboard LAN 3 - PCIe Link
Speed Error
Link Speed error was detected on
onboard LAN3.
B264
Onboard LAN 4 - PCIe Link
Speed Error
Link Speed error was detected on
onboard LAN4.
B271
PCI Slot 1 - PCIe Link Speed
Error
Link Speed error was detected on PCI
Slot 1.
B272
PCI Slot 2 - PCIe Link Speed
Error
Link Speed error was detected on PCI
Slot 2.
B800
DXE_PCI_BUS_OUT_OF_RESOURCES
Resources to be allocated to PCI
expansion card was insufficient.
C000
The error occurred during
fan sensor reading.
An error was detected while reading
fan sensor.
C010
The error occurred during
temperature sensor reading
An error was detected while reading
temperature sensor.
C011
System Temperature out of
the range.
A temperature abnormality was
detected.
It is possible that a fan has failed or is
clogged.
Contact your sales representative.
C020
The error occurred during
voltage sensor reading.
An error was detected while reading
voltage sensor.
Contact your sales representative.
C021
System Voltage out of the
range.
A system voltage abnormality was
detected.
C040
SROM data read error
An error was detected while reading
data on SROM.
C061
1st SMBus device Error
detected.
An error was detected on 1st SM Bus.
C062
2nd SMBus device Error
detected.
An error was detected on 2nd SM
Bus.
C063
3rd SMBus device Error
detected.
An error was detected on 3rd SM Bus.
C064
4th SMBus device Error
detected.
An error was detected on 4th SM Bus.
C065
5th SMBus device Error
detected.
An error was detected on 5th SM Bus.
C066
6th SMBus device Error
detected.
An error was detected on 6th SM Bus.
C067
7th SMBus device Error
detected.
An error was detected on 7th SM Bus.
C068
8th SMBus device Error
detected.
An error was detected on 8th SM Bus.
C101
BMC Memory Test
Failed.
An error was detected on BMC.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the
same error is detected repeatedly, contact
your sales representative.
C102
BMC Firmware Code
Area CRC check Failed.
C103
BMC core hardware failure.
C104
BMC IBF or OBF check failed.
An error was detected while
accessing BMC.
C105
BMC SEL area full.
There is not enough space to store
the system event log.
Run Offline Tools (
Chapter 1, 9. Offline
Tools
) and delete the event logs.