Troubleshooting 7-29
standard.
Is BIOS configuration correct?
→
The internal LAN controller may be disabled with the BIOS setup utility of the
server. Check the setting with the BIOS setup utility.
<Menu to check: [Advanced]
→
[Option Rom]
→
[On Board LAN]>
Have the protocol and service already configured?
→
Install the distinctive network driver for the server. Make sure that the protocol,
such as TCP/IP, and services are properly specified.
Is the transfer speed correct?
→
Open the [Network Property] dialog box in control panel to specify the “Link Speed
& Dual” value the same as the value specified for HUB.
Icon of drive A is changed to that of removal disk:
→
Does not cause any problem.
"The NMS Service service terminated unexpectedly." is recorded in the system event log:
→
Although the following log may be recorded in the system event log when starting
the system, or after exchanging PCI modules, there is no real problem on
operation. Change of a setup with PROSet II will become invalid if NMS service
stops, but you can change a setup normally because NMS service will be
automatically started when PROSet II is started.
“Source:
Service Control Manager
Event ID:
7031
Description: The NMS service terminated unexpectedly.This has occurred 1
time(s). The following corrective action will be taken in 0
milliseconds: No action.”
iANSMiniport-related logs are recorded in the system event log:
→
Although the following log may be recorded in the system event log when starting
the system, there is no real problem on operation (In the description, “X”
represents a number).
“Source:
iANSMiniport
Event ID:
35
Description: Initializing Team #X missing adapters. Check the configuration to
verify that all the adapters are present and functioning.”
Содержание Express5800/320Lb FT Linux
Страница 1: ...N8800 027F 028F NEC Express5800 320Lb 320Lb R User s Guide 1st Edition 02 2003 856 122693 901 A ...
Страница 10: ...iv This page is intentionally left blank ...
Страница 16: ...x This page is intentionally left blank ...
Страница 19: ...Precautions for Use 1 3 Label A Label B Label C Label E Label D ...
Страница 20: ...1 4 Precautions for Use Rack mount model Label B Label A Label C Label D ...
Страница 21: ...Precautions for Use 1 5 Label D Label C Label B Label A ...
Страница 22: ...1 6 Precautions for Use PCI CPU Modules PCI Module CPU Module Label A Label A Label A ...
Страница 36: ...1 20 Precautions for Use This page is intentionally left blank ...
Страница 44: ...2 8 General Description Front View inside Tower model Rack mount model ...
Страница 70: ...2 34 General Description This page is intentionally left blank ...
Страница 71: ...Chapter 3 Setup This chapter describes setup procedures to make NEC Express5800 ft series ready for use ...
Страница 118: ...3 48 Setup This page is intentionally left blank ...
Страница 162: ...4 44 System Configuration This page is intentionally left blank ...
Страница 217: ...Installing and Using Utilities 5 55 Also at this time the state of the mirrored disks change to Normal Mirror Disk ...
Страница 294: ...6 14 Maintenance This page is intentionally left blank ...
Страница 295: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown ...
Страница 336: ...7 42 Troubleshooting This page is intentionally left blank ...
Страница 355: ...System Upgrade 8 19 15 Check the disk you selected and click Next 16 Click Complete ...
Страница 399: ...System Upgrade 8 63 Cable ties included with cabinet ...
Страница 410: ...8 74 System Upgrade This page is intentionally left blank ...
Страница 412: ...A 2 Specifications This page is intentionally left blank ...