System Details 41
Version 2.21
US/Canada specification
Temperature range
Increase/ decrease
value
[+] key
[+] continuous key
operation
[-] key
[-] continuous key
operation
98~120°F (36~50°C)
1°F( 0.5°C)
Short key
Increased every
100msec
Short Key
Decreased every
100msec
120~140°F
(50~60°C)
5°F ( 2°C )
2sec Long Key
Not working
Short Key
Decreased every
100msec
140~182°F
(60~83°C)
10°F ( 5°C)
180°F (80°C)
<->
182 (83°C)
5sec Long Key
Not working
Short Key
Decreased every
100msec
4.7.13 Viewing Basic Information
1. At the <Normal operation mode>, press the [Info] button once to access the Information Data.
2. Whenever the [+] / [-] button is pressed, the Information Data item can be selected and displayed.
3. The data items being currently outputted are displayed by an LED ICON. (Flow rate-GPM/LPM, leaving water temperature-OUT, entering
water temperature-IN)
4. Press the [Reset] button once to return to the <Normal operation mode>.
5. If there is no button input for 5 minutes, it automatically returns to the <Normal operation mode>.
Item
Description
Display method
Flow rate
●
Display of the current flow rate
●
Minimum display unit: 0.2 Gal/min or
l/min
GPM flow rate display
ex )10.2GPM
Water temperature
●
Gal/min or l/min
●
Display of the current outgoing water
temperature
OUT temperature display
ex) 120°F
●
Display of the current incoming water
temperature
IN temperature display
ex)120°F