Troubleshooting 77
Scenario2
Check the flame rod
Power OFF the unit
Check connector
Check that gas valve is open or
check LP supply
Check the voltage between #1 and #3 of CON 4:
22-24 VDC
Check the voltage between #2 and #3 of CON 4:
22-24 VDC
(see page 52 for Wiring Diagram)
In case of LP gas model, low gas pressure can cause
“Ignition Failure”.
* Normal gas pressure: 8.0 - 13.0" w. c.
NO
NO
NO
Yes
Yes
Yes
Is gas valve operating
normally?
Does the main
gas valve have proper
voltage?
Is gas valve open?
Scenario3
Restart unit
Check connector
(#1 of CON10)
Clean or replace the flame rod
Check whether ground circuit is
properly installed.
Check the current #1 of CON 10: 1 - 20μA
(see page 52 for Wiring Diagram)
NO
NO
Yes
Yes
Is the flame detection
device normally
operating?
Is the flame current
detected?
Содержание NPE-180A