Troubleshooting 89
Check method
Fault
Possible Causes
Check method
Defective safety device
Defective overheat
controller
Check if the contact point of the overheat controller is defective.
●
Use a multimeter to see if the resistance is normal (0.3Ω) or abnormal (∞).
Overheat controller
Check if the overheat controller wire is
disconnected ( Normal 0.3Ω )
Temperature sensor
error
Defective hot water
output temperature
sensor
1. If the hot water temperature is sensed lower than it actually is due to a defective
sensor, check if the deviation of temperature is large due to a defective
temperature sensor.
●
Check the output temperature displayed on the front panel.
2. Measure the temperature sensor resistance, and determine if the sensor is
defective.