Version 2.21
16 NPE Service Manual
3.1 General Specifications
The following table lists the specifications for the water heater. Additional specifications about water, gas, electric, and air supplies (venting)
appear in the Installation section.
Item
NPE-150S
NPE-180(A) NPE-180S
NPE-210(A) NPE-210S
NPE-240(A)
NPE-240S
Heat
Capacity
(Input)
Natural Gas
18,000-
120,000
BTU/H
15,000-150,000 BTU/H
19,900-180,000 BTU/H
19,900-199,900 BTU/H
Propane Gas
15,000-150,000 BTU/H
19,900-180,000 BTU/H
19,900-199,900 BTU/H
Energy
Factor
UEF
(for NG & LP)
0.96
0.96
0.97
0.96
0.97
0.96
0.97
EF (Canada)
(for NG & LP)
0.97
0.97
0.99
0.97
0.99
0.97
0.99
Flow Rate
(DHW)
35 °F (19 °C) Temp Rise
6.8 GPM
(25.8 L/m)
8.4 GPM (32 L/m)
10.1 GPM (38 L/m)
11.2 GPM (42 L/m)
45 °F (25 °C) Temp Rise
5.3 GPM
(20 L/m)
6.5 GPM (25 L/m)
7.8 GPM (30 L/m)
8.7 GPM (33 L/m)
67 °F (36 °C) Temp Rise
3.2 GPM
(12 L/m)
4.3 GPM
(16 L/m)
4.2 GPM
(16 L/m)
5.0 GPM
(19 L/m)
5.2 GPM
(20 L/m)
5.6 GPM
(21 L/m)
5.7 GPM
(22 L/m)
Dimensions
17.3 in (W) x 27.4 in (H) x 13.2 in (D)
Weight
62 lbs
(28 kg)
75 lbs
(34 kg)
67 lbs
(30 kg)
82 lbs
(37 kg)
75 lbs
(34 kg)
82 lbs
(37 kg)
75 lbs
(34 kg)
Installation Type
Indoor or Outdoor Wall-Hung
Venting Type
Forced Draft Direct Vent
Ignition
Electronic Ignition
Water Pressure
15-150 PSI
Natural Gas Supply Pressure
(from source)
3.5 in WC-10.5 in WC
Propane Gas Supply Pressure
(from source)
8 in WC-13in WC
Natural Gas Manifold Pressure
(min-max)
-0.04 in WC -
-0.40 in WC
-0.04 in WC - -0.84 in WC
-0.05 in WC - -0.36 in WC
-0.05 in WC - -0.58 in WC
Propane Gas Manifold Pressure
(min-max)
-0.05 in WC -
-0.42 in WC
-0.05 in WC - -0.50 in WC
-0.10 in WC - -0.66 in WC
-0.10 in WC - -0.78 in WC
Minimum Flow Rate
0 GPM (0 L/m) for “A” models / 0.5 GPM (1.9 L/m) for “S” models
Connection
Sizes
Cold Water Inlet
3
/
4
in NPT
Hot Water Outlet
3
/
4
in NPT
Gas Inlet
3
/
4
in NPT
Power
Supply
Main Supply
120 V AC, 60 Hz
Maximum Power
Consumption
200 W (max 2 A), 350 W (max 4 A) with external pump connected
Materials
Casing
Cold Rolled Carbon Steel
Heat Exchangers
Primary Heat Exchanger: Stainless Steel
Secondary Heat Exchanger: Stainless Steel
Venting
Exhaust
2 in or 3 in PVC, CPVC, Polypropylene
2 in or 3 in Special Gas Vent Type BH (Class II, A/B/C)
Intake
2 in or 3 in PVC, CPVC, Polypropylene
2 in or 3 in Special Gas Vent Type BH (Class II, A/B/C)
Vent Clearances
0 in to combustibles
Safety
Devices
Flame Rod, APS, Ignition Operation Detector, Water Temperature High Limit Switch, Exhaust Temperature High Limit Sensor,
Power Surge Fuse
3. Technical Data
Содержание NPE-180A
Страница 3: ......
Страница 57: ...Version 2 21 56 NPE Service Manual 4 10 Electrical Diagnostic Points ...
Страница 86: ...Troubleshooting 85 ...
Страница 156: ...Installation the Outdoor Vent Cover 155 9 5 Ventilation Flow Intake Air Flow Exhaust Gas Flow ...