Version 2.21
90 NPE Service Manual
Fault
Possible Causes
Check method
Other trouble
Capacity setting
1. If the Max switch #1 of 1-1 is on,
Set the switch to the normal operation position.
2. PCB DIP S/W capacity setting error can suddenly increase the hot water
temperature.
●
Check the PCB DIP S/W capacity setting.(refer to page 21)
DIP SWITCH 1-1
DIP SWITCH 1-2
NPE-150
1 2 3 4
ON
1 2 3 4 5 6
ON
NPE-180
1 2 3 4 5 6
ON
NPE-210
1 2 3 4 5 6
ON
NPE-240
1 2 3 4 5 6
ON
●
2-switch Panel:
Switch
Function
Setting
1
Cascade Vent
Common Vent
1-OFF
Individual Vent
1-ON
2
Gas Type
Natural Gas
2-OFF
Propane Gas
2-ON
1 2 3 4 5 6 7 8 9 10
ON
ON
ON
1 2 3 4
1 2 3 4 5 6
ON
DIP S/W 1-1
DIP S/W 1-2
Primary heat
exchanger overheated
The surface temperature rises due to heavy scale deposits in the primary heat
exchanger.
●
Flush the primary heat exchanger.
Defective PCB
If the issue continues despite checking the items above, the PCB is defective.