Version 2.21
72 NPE Service Manual
4.11.15 Circulation Pump (“A” models only)
Part
Check Point
Function
1. Pump operates when using internal or external hot water circulation.
2. Internal circulation will minimize the effect of temperature fluctuations and external circulation delivers hot
water to fixtures quickly resulting in water conservation.
Failure Event
Unable to detect or measure water flow rate when the pump is called to operate.
Effects
1. The water heater freezes.
2. Temperature fluctuations when the water heater is set to internal recirculation.
3. Hot water is not quickly available at fixtures when the water heater is set to external recirculation.
Error Code
E438
Diagnostic
1. Visual inspection: Check the circulation pump connection wire.
* Check for blocked/clogged water filter.
2. Voltage check: Check range of voltage shown below.
Color/Number
of wires
YELLOW-WHITE
●
ON : AC 96 ~138 V
●
OFF : 0V
Содержание NPE-180A
Страница 3: ......
Страница 57: ...Version 2 21 56 NPE Service Manual 4 10 Electrical Diagnostic Points ...
Страница 86: ...Troubleshooting 85 ...
Страница 156: ...Installation the Outdoor Vent Cover 155 9 5 Ventilation Flow Intake Air Flow Exhaust Gas Flow ...