Safety Information 11
WARNING
●
Shut off the gas supply if the water heater is damaged.
Have your installer or plumber show you the location of the
gas shut off valve and demonstrate how to close the valve. If
the water heater is damaged as a result of overheating, fire,
flood, or any other reason, close the manual shut off valve
and do not operate the water heater again until it has been
inspected by a qualified technician.
●
Do not store or use gasoline or other flammable liquids
near this water heater.
Doing so may result in fire or explosion.
●
Do not place combustibles, such as newspapers or
laundry, near the water heater or venting system.
Doing so may result in a fire.
●
Do not place or use hair sprays, spray paints, or any other
compressed gases near the water heater or venting
system, including the vent termination.
Doing so may result in fire or explosion.
●
Do not operate the water heater with the front cover
opened.
Doing so may result in fire or carbon monoxide (CO)
poisoning, which may result in property damage, personal
injury, or death.
●
Do not operate this water heater without proper venting.
Doing so may result in fire or carbon monoxide (CO)
poisoning, which may result in property damage, personal
injury, or death. Inspect the vent termination and air intake
supply annually to ensure proper operation of the water
heater. Turn off and discontinue use of the water heater
if any of the vent pipes, vent elbows, or intake pipes are
damaged in any way, separated at a joint, or show evidence
of corrosion, rusting, or melting.
●
Do not touch the power cord or internal components of
the water heater with wet hands.
Doing so may result in electric shock.
WARNING
GAS TYPE and AC VOLTAGE
This water heater is configured for Natural Gas from the factory.
If conversion to Propane Gas is required, the conversion kit
supplied with the water heater must be used.
●
Be sure to use 120 VAC, 60 Hz, minimum 2 A current. Using
abnormally high or low AC voltage may cause abnormal
operation, and may reduce the life expectancy of this
product.
If the unit does not match requirements, do not service,
please contact Navien immediately.
WARNING
GAS CONVERSION
The conversion kit shall be installed by a qualified service
agency* in accordance with Navien’s instructions and all
applicable codes and requirements of the authority having
jurisdiction. The information in these instructions must be
followed to minimize the risk of fire or explosion or to prevent
property damage, personal injury or death. The qualified
service agency is responsible for the proper installation of
this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specified in
the manufacturer’s instructions supplied with the kit.
* A qualified service agency is any individual, firm, corporation
or company which either in person or through a representative
is engaged in and is responsible for the connection, utilization,
repair or servicing of gas utilization equipment or accessories;
who is experienced in such work, familiar with all precautions
required, and has complied with all of the requirements of the
authority having jurisdiction.
In Canada:
The conversion shall be carried out in accordance
with the requirements of the provincial authorities having
jurisdiction and in accordance with the requirements of the
CAN‐B149.1 and CAN1‐B149.2 Installation Code.
Navien, Inc. is not liable for any property damage and/or
personal injury resulting from unauthorized conversions.